Title and reference
2003/593/EC: Commission Decision of 7 August 2003 amending Decision 2003/43/EC establishing the classes of reaction-to-fire performance of certain construction products (Text with EEA relevance) (notified under document number C(2003) 2592)
?OJ L 201, 8.8.2003, p. 25–27 (ES, DA, DE, EL, EN, FR, IT, NL, PT, FI, SV)
?Special edition in Czech: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Estonian: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Hungarian Chapter 13 Volume 31 P. 399 - 401
?Special edition in Lithuanian: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Latvian: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Maltese: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Polish: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Slovakian: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Slovenian: Chapter 13 Volume 31 P. 399 - 401
?Special edition in Bulgarian: Chapter 13 Volume 40 P. 100 - 102
?Special edition in Romanian: Chapter 13 Volume 40 P. 100 - 102
?DA?DE?EL?EN?ES?FI?FR?IT?NL?PT?SV
Text
| BG | ES | CS | DA | DE | ET | EL | EN | FR | GA | IT | LV | LT | HU | MT | NL | PL | PT | RO | SK | SL | FI | SV |
| ? | html | html | html | html | html | html | html | html | ? | html | html | html | html | html | html | html | html | ? | html | html | html | html |
| ? | ||||||||||||||||||||||
| tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff |
Dates
- of document: 07/08/2003
of notification: 07/08/2003
of effect: 07/08/2003; Entry into force Date notif.
end of validity: 99/99/9999
Classifications
- EUROVOC descriptor:
building materials
building safety
fire protection
product safety
safety standard - Directory code:
13.30.99.00 Industrial policy and internal market / Internal market: approximation of laws / Other sectors for approximation of laws - Subject matter:
Internal market, Technical barriers
Miscellaneous information
- Author:
European Commission - Form:
Decision - Addressee:
The Member States - Additional information:
EEA relevance
Relationship between documents
- Treaty:
European Community - Legal basis:
31989L0106 -A20P2 - Select all documents based on this document
- Amendment to:
32003D0043 Amendment Completion Annex from /T/DATN - Instruments cited:
32000D0147 - Select all documents mentioning this document
Text
| Bilingual display: BG CS DA DE EL EN ES ET FI FR HU IT LT LV MT NL PL PT RO SK SL SV |
Commission Decision
of 7 August 2003
amending Decision 2003/43/EC establishing the classes of reaction-to-fire performance of certain construction products
(notified under document number C(2003) 2592)
(Text with EEA relevance)
(2003/593/EC)
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Council Directive 89/106/EEC of 21 December 1988, on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products(1), as amended by Directive 93/68/EEC(2), and in particular Article 20(2) thereof,
Whereas:
(1) Commission Decision 2003/43/EC(3) establishes classes of reaction-to-fire performance of certain construction products, namely wood-based panel products.
(2) Decision 2003/43/EC should be adapted to technical progress through the inclusion of certain gypsum products, certain high-pressure decorative laminate panels and certain structural timber products in conformity with the classification established in Commission Decision 2000/147/EC of 8 February 2000 implementing Council Directive 89/106/EEC as regards the classification of the reaction-to-fire performance of construction products(4).
(3) Decision 2003/43/EC should therefore be amended accordingly.
(4) The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,
HAS ADOPTED THIS DECISION:
Article 1
The Annex to Decision 2003/43/EC is amended as set out in the Annex to this Decision.
Article 2
This Decision is addressed to the Member States.
Done at Brussels, 7 August 2003.
For the Commission
Erkki Liikanen
Member of the Commission
(1) OJ L 40, 11.2.1989, p. 12.
(2) OJ L 220, 30.8.1993, p. 1.
(3) OJ L 13, 18.1.2003, p. 35.
(4) OJ L 50, 23.2.2000, p. 14.
ANNEX
In the Annex to Decision 2003/43/EC, the following Tables and note shall be added:
"
TABLE 2
Classes of reaction-to-fire performance of gypsum plasterboard products
>TABLE>
Note: End Use Application
The gypsum plasterboards shall be mounted and fixed using one of the two following methods:
(a) Mechanically fixed to a supporting substructure
The boards, or (in the case of multi-layer systems) at least the outermost layer of boards, shall be mechanically fixed to a metal substructure (made from components detailed in EN 14195) or a timber substructure (in accordance with EN 336 and ENV 1995-5).
When the substructure provides supporting members in one direction only, the maximum span between the supporting members shall not exceed a dimension equal to 50 times the thickness of the boards. When the substructure includes supporting members in two directions the maximum span in either direction shall not exceed a dimension equal to 100 times the thickness of the boards.
The mechanical fixings shall be screws or nails, which shall be fixed through the thickness of the boards into the substructure at centres not exceeding 300 mm measured along the length of each supporting member.
All joints between adjoining boards shall be fully filled with jointing compound as specified in EN 13963.
The cavity formed behind the boards by the substructure may provide an air space, or may be filled with an insulating material with a reaction to fire classification of at least class A2-s1, d0.
(b) Directly fixed or bonded to a solid substrate (dry lining system)
The boards shall be fixed directly to a solid substrate with a reaction to fire classification of at least class A2-s1, d0.
The boards may be fixed using screws or nails fixed through the thickness of the boards into the solid substrate or may be bonded to the substrate using 'dabs' of gypsum based adhesive compound. In either case the screw or nail fixings or the adhesive 'dabs' shall be positioned at maximum 600 mm vertical and horizontal centres.
All joints between adjoining boards shall be fully filled with jointing compound as specified in EN 13963.
TABLE 3
Classes of reaction-to-fire performance of high-pressure decorative laminate panels
>TABLE>
TABLE 4
Classes of reaction-to-fire performance of structural timber products((Applies to all species covered by the product standards.))
>TABLE>"
| Top |
托管标准,您可以接收以下服务:
1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;
2 随时在标准托管页面中查看到该条标准的最新状态;
3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;
4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;
5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;
6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;
标准资讯点击排行榜 全部
资讯标题点击
[[ n.title ]] [[ n.read ]]大连标准化公共服务平台
版权:大连标准化研究院有限公司
地址:大连市中山区高原街56号
电话:0411-82740851