委员会决定2006/99/EC,修订批准英国猪胴体评级措施的决定2004/370/EC(根据文件C(2006) 213通报)
技术法规类型:欧盟Eurlex法规 来源:tbtmap
EURLEX ID:32006D0099
OJ编号:OJ L 46, 16.2.2006, p. 34-37
中文标题:委员会决定2006/99/EC,修订批准英国猪胴体评级措施的决定2004/370/EC(根据文件C(2006) 213通报)
原文标题:2006/99/EC: Commission Decision of 3 February 2006 amending Decision 2004/370/EC authorising methods for grading pig carcases in the United Kingdom (notified under document number C(2006) 213)
分类:03.60.52_猪肉
文件类型:二级立法 Decision|决定
废止日期:2058-12-31
法规全文:查看欧盟官方文件
32006D0099
Title and reference
2006/99/EC: Commission Decision of 3 February 2006 amending Decision 2004/370/EC authorising methods for grading pig carcases in the United Kingdom (notified under document number C(2006) 213)
?OJ L 46, 16.2.2006, p. 34–37 (ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, NL, PL, PT, SK, SL, FI, SV)
?CS?DA?DE?EL?EN?ES?ET?FI?FR?HU?IT?LT?LV?NL?PL?PT?SK?SL?SV
Text
| BG | ES | CS | DA | DE | ET | EL | EN | FR | GA | IT | LV | LT | HU | MT | NL | PL | PT | RO | SK | SL | FI | SV |
| ? | html | html | html | html | html | html | html | html | ? | html | html | html | html | ? | html | html | html | ? | html | html | html | html |
| ? | ? | ? | ? | |||||||||||||||||||
| tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff |
Authentic language
- English
Dates
- of document: 16/02/2006
of notification: 00/00/0000
of effect: 00/00/0000; Entry into force See Art 2
end of validity: 99/99/9999
Classifications
- EUROVOC descriptor:
carcase
swine
pigmeat
Northern Ireland
measuring equipment
agricultural product nomenclature
statistical method - Directory code:
03.60.52.00 Agriculture / Products subject to market organisation / Pigmeat
- Subject matter:
Veterinary legislation
Miscellaneous information
- Author:
European Commission - Form:
Decision - Addressee:
United Kingdom
Relationship between documents
- Treaty:
European Community - Legal basis:
31984R3220 -A05P2
- Select all documents based on this document
- Amendment to:
32004D0370 Amendment Replacement Annex 2 from /T/DATN
32004D0370 Amendment Replacement Article 2 from /T/DATN
- Select all documents mentioning this document
Text
| Bilingual display: CS DA DE EL EN ES ET FI FR HU IT LT LV NL PL PT SK SL SV |
Commission Decision
of 3 February 2006
amending Decision 2004/370/EC authorising methods for grading pig carcases in the United Kingdom
(notified under document number C(2006) 213)
(Only the English text is authentic)
(2006/99/EC)
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Council Regulation (EEC) No 3220/84 of 13 November 1984 determining the Community scale for grading pig carcases [1], and in particular Article 5(2) thereof,
Whereas:
(1) By Commission Decision 2004/370/EC [2], the use of three methods for grading pig carcases in Northern Ireland has been authorised.
(2) Due to technical adaptations, the United Kingdom has requested the Commission to authorise in Northern Ireland the use of new formulae for two apparata used for grading pig carcases and to authorise two new methods for grading pig carcases, and has therefore submitted the elements required in Article 3 of Commission Regulation (EEC) No 2967/85 of 24 October 1985 laying down detailed rules for the application of the Community scale for grading pig carcases [3]. As the apparatus "Fat-O-Meater" has never been used in Northern Ireland, it should be deleted from the scope of this Decision concerning Northern Ireland.
(3) The evaluation of this request has revealed that the conditions for using the new formulae and the new methods are fulfilled.
(4) Decision 2004/370/EC should therefore be amended accordingly.
(5) The measures provided for in this Decision are in accordance with the opinion of the Management Committee for Pigmeat,
HAS ADOPTED THIS DECISION:
Article 1
Decision 2004/370/EC is amended as follows:
1. Article 2 is replaced by the following:
"Article 2
The use of the following methods is hereby authorised for grading pig carcases pursuant to Regulation (EEC) No 3220/84 in Northern Ireland:
- the apparatus termed "Intrascope (Optical Probe)" and assessment methods related thereto, details of which are given in Part 1 of Annex II,
- the apparatus termed "Mark II Ulster Probe" and assessment methods related thereto, details of which are given in Part 2 of Annex II,
- the apparatus termed "Hennessy Grading Probe (HGP 4)" and assessment methods related thereto, details of which are given in Part 3 of Annex II,
- the apparatus termed "Fully automatic ultrasonic carcass grading (Autofom)" and assessment methods related thereto, details of which are in Part 4 of Annex II."
2. Annex II is amended in accordance with the Annex to this Decision.
Article 2
This Decision is addressed to the United Kingdom of Great Britain and Northern Ireland.
Done at Brussels, 3 February 2006.
For the Commission
Mariann Fischer Boel
Member of the Commission
[1] OJ L 301, 20.11.1984, p. 1. Regulation as last amended by Regulation (EC) No 3513/93 (OJ L 320, 22.12.1993, p. 5).
[2] OJ L 116, 22.4.2004, p. 32.
[3] OJ L 285, 25.10.1985, p. 39. Regulation as amended by Regulation (EC) No 3127/94 (OJ L 330, 21.12.1994, p. 43).
--------------------------------------------------
ANNEX
Annex II to Decision 2004/370/EC is hereby amended as follows:
1. Point 3 of Part 1 (Intrascope (Optical Probe)) is replaced by the following:
"3. The lean meat content of the carcase shall be calculated according to the following formula:
+++++ TIFF +++++
= 71,4802 – 0,83659 x
where:
+++++ TIFF +++++
= the estimated lean meat percentage in the carcase,
x = the thickness of the backfat (including rind) in millimetres measured at 6 centimetres off the midline of the carcase at the last rib (known as "P2")
The formula shall be valid for carcases weighing between 50 and 140 kilograms."
2. Point 3 of Part 2 (Mark II Ulster Probe) is replaced by the following:
"3. The lean meat content of the carcase shall be calculated according to the following formula:
+++++ TIFF +++++
= 71,4384 – 0,84119 x
where:
+++++ TIFF +++++
= the estimated lean meat percentage in the carcase,
x = the thickness of the backfat (including rind) in millimetres measured at 6 centimetres off the midline of the carcase at the last rib (known as "P2")
The formula shall be valid for carcases weighing between 50 and 140 kilograms."
3. Part 3 is replaced by the following:
"PART 3
Hennessy Grading Probe (HGP 4)
1. Grading of pig carcases shall be carried out by means of the apparatus termed "Hennessy Grading Probe (HGP 4)".
2. The apparatus shall be equipped with a probe of 5,95 millimetres diameter (and of 6,3 millimetres at the blade of the top of the probe) containing a photodiode (Siemens LED of the type LYU 260-EO and photodetector of the type 58 MR) and having an operating distance of between 0 and 120 millimetres. The results of the measurements shall be converted into estimated lean meat content by means of the HGP 4 itself or a computer linked to it.
3. The lean meat content of the carcase shall be calculated according to the following formula:
+++++ TIFF +++++
= 71,5278 – 0,86638 x
where:
+++++ TIFF +++++
= the estimated lean meat percentage in the carcase,
x = the thickness of the backfat (including rind) in millimetres measured at 6 centimetres off the midline of the carcase at the last rib (known as "P2")
The formula shall be valid for carcases weighing between 50 and 140 kilograms."
4. The following Part 4 is added:
"PART 4
Fully automatic ultrasonic carcass grading (Autofom)
1. Pig carcase grading shall be carried out using the apparatus termed Autofom (Fully automatic ultrasonic carcass grading).
2. The apparatus shall be equipped with 16 16,2 MHz ultrasonic transducers (Krautkr?mer, SFK 2 NP), with an operating distance between transducers of 25 mm.
The ultrasonic data shall comprise measurements of back-fat thickness and muscle thickness.
The results of the measurements are converted into estimated lean meat content using a computer.
3. The carcase's lean meat content shall be calculated on the basis of 127 measurement points using the following formula:
+++++ TIFF +++++
= b0 + ip1b1 + ip2b2+ ip3b3+… ip127b127.
where:
+++++ TIFF +++++
= the estimated lean meat content of the carcase,
ip1-ip127 = Input parameters of Autofom image analysis
b0-b127 = Constants from the model calibration
The 127 b-coefficients are, in order IP1-IP127:
– 1,6866978E-002
– 2,7395384E-002
– 1,9907279E-002
– 8,5862307E-003
– 1,7233329E-002
– 1,2928455E-002
– 7,2069578E-003
0,0000000E+000
0,0000000E+000
9,9210571E-003
– 2,7280254E-002
– 1,1866679E-002
– 1,6877903E-002
– 3,3714309E-002
– 2,2873893E-002
– 1,2976709E-002
– 1,9736953E-002
0,0000000E+000
– 1,0441692E-002
– 2,6023159E-002
– 1,6019909E-002
– 1,2085976E-002
– 2,0802582E-002
– 1,2004912E-002
4,9544591E-003
2,1012272E-003
3,5626963E-003
5,4210355E-003
2,8231265E-003
0,0000000E+000
3,4462682E-003
4,9613826E-003
3,1486694E-003
0,0000000E+000
3,3405393E-003
0,0000000E+000
0,0000000E+000
1,0592665E-003
0,0000000E+000
0,0000000E+000
2,3835478E-003
0,0000000E+000
– 2,3957171E-002
– 1,6251475E-002
0,0000000E+000
– 2,1446949E-002
0,0000000E+000
– 2,4741126E-002
– 2,2376098E-002
– 1,6962735E-002
– 2,8594572E-002
– 1,9001560E-002
– 2,7471537E-002
– 3,2565221E-002
– 3,1170983E-002
– 2,9708274E-002
– 2,7283320E-002
– 2,5577871E-002
– 3,2280222E-002
– 3,1662315E-002
– 3,3039205E-002
– 3,2290529E-002
– 3,0902216E-002
– 2,9116826E-002
– 2,5646536E-002
– 2,3514079E-002
– 2,7472775E-002
– 2,6122212E-002
– 2,3694078E-002
– 2,7969513E-002
– 2,8660055E-002
– 2,8413385E-002
– 3,2624107E-002
– 3,2517981E-002
– 3,1576648E-002
– 3,1543616E-002
– 3,1162977E-002
– 3,0734278E-002
– 3,4127805E-002
– 3,4164313E-002
– 3,4327772E-002
– 3,4017213E-002
– 3,3313580E-002
– 3,3459395E-002
– 2,4075206E-002
– 2,5336761E-002
– 2,6048595E-002
– 2,6499119E-002
– 2,6947299E-002
– 2,7433341E-002
– 3,1328205E-002
– 3,1818397E-002
– 2,7329659E-002
6,0837399E-003
6,8703182E-003
7,7951970E-003
8,3265398E-003
7,6311678E-003
6,6542262E-003
5,8027613E-003
8,4376512E-003
8,3114961E-003
8,2320096E-003
8,0569442E-003
7,7763004E-003
7,6648975E-003
7,3420489E-003
7,2652618E-003
7,1755257E-003
7,1458751E-003
7,1670651E-003
6,9467919E-003
7,0396927E-003
7,2869365E-003
5,7384889E-003
7,6241307E-003
7,3343012E-003
6,9868541E-003
6,6073379E-003
6,9390922E-003
6,3295597E-003
6,0446505E-003
1,0994689E-002
9,2938738E-003
4,4189114E-003
4,3836362E-003
4,6389205E-003
The b0-coefficient is 6,3457577E+001
4. Descriptions of the measurement points and the statistical method can be found in Part II of the United Kingdom protocol forwarded to the Commission in accordance with Article 3(3) of Regulation (EEC) No 2967/85.
The formula shall be valid for carcases weighing between 50 and 140 kilograms."
--------------------------------------------------
| Top |
托管标准,您可以接收以下服务:
1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;
2 随时在标准托管页面中查看到该条标准的最新状态;
3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;
4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;
5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;
6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;
标准资讯点击排行榜 全部
资讯标题点击
[[ n.title ]] [[ n.read ]]大连标准化公共服务平台
版权:大连标准化研究院有限公司
地址:大连市中山区高原街56号
电话:0411-82740851