委员会条例(EC) No 1497/2007,根据欧洲议会和理事会条例 (EC) No 842/2006,建立含有特定含氟温室气体的固定消防系统的标准泄露检测要求(内容与EEA相关)
技术法规类型:欧盟Eurlex法规 来源:tbtmap
EURLEX ID:32007R1497
OJ编号:OJ L 333, 19.12.2007, p. 4-5
中文标题:委员会条例(EC) No 1497/2007,根据欧洲议会和理事会条例 (EC) No 842/2006,建立含有特定含氟温室气体的固定消防系统的标准泄露检测要求(内容与EEA相关)
原文标题:Commission Regulation (EC) No 1497/2007 of 18 December 2007 establishing, pursuant to Regulation (EC) No 842/2006 of the European Parliament and of the Council, standard leakage checking requirements for stationary fire protection systems containing certain fluorinated greenhouse gases (Text with EEA relevance)
分类:15.10.20.30_大气污染监测
文件类型:二级立法 Regulation|条例
生效日期:2008-01-08
废止日期:2058-12-31
法规全文:查看欧盟官方文件
32007R1497
Title and reference
Commission Regulation (EC) No 1497/2007 of 18 December 2007 establishing, pursuant to Regulation (EC) No 842/2006 of the European Parliament and of the Council, standard leakage checking requirements for stationary fire protection systems containing certain fluorinated greenhouse gases (Text with EEA relevance)
OJ L 333, 19.12.2007, p. 4‘� (BG, ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)
BG CS DA DE EL EN ES ET FI FR HU IT LT LV MT NL PL PT RO SK SL SV
Text
| BG | ES | CS | DA | DE | ET | EL | EN | FR | GA | IT | LV | LT | HU | MT | NL | PL | PT | RO | SK | SL | FI | SV |
| html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | html | |
| tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff |
Dates
- of document: 18/12/2007
of effect: 08/01/2008; Entry into force Date pub. + 20 See Art 8
end of validity: 99/99/9999
Classifications
- EUROVOC descriptor:
greenhouse gas
fire protection
environmental standard
risk prevention
degree of pollution
pollution control - Directory code:
15.10.20.30 Environment, consumers and health protection / Environment / Pollution and nuisances / Monitoring of atmospheric pollution
- Subject matter:
Environment
Miscellaneous information
- Author:
European Commission - Form:
Regulation - Additional information:
EEA relevance
Relationship between documents
- Treaty:
European Community - Legal basis:
32006R0842 -A03P7
- Select all documents based on this document
- Instruments cited:
32000R2037
- Select all documents mentioning this document
Text
| Bilingual display: BG CS DA DE EL EN ES ET FI FR HU IT LT LV MT NL PL PT RO SK SL SV |
20071218
Commission Regulation (EC) No 1497/2007
of 18 December 2007
establishing, pursuant to Regulation (EC) No 842/2006 of the European Parliament and of the Council, standard leakage checking requirements for stationary fire protection systems containing certain fluorinated greenhouse gases
(Text with EEA relevance)
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Regulation (EC) No 842/2006 of the European Parliament and of the Council of 17 May 2006 on certain fluorinated greenhouse gases [1], and in particular Article 3(7) thereof,
Whereas:
(1) In fire protection systems comprising several interconnected containers installed in response to a specific fire risk in a defined space, the charge of fluorinated greenhouse gases should be calculated on the basis of the total charge of those containers in order to ensure that the frequency of the checks corresponds to the effective charge of fluorinated greenhouse gases.
(2) Pursuant to Regulation (EC) No 842/2006, records for fire protection systems shall contain certain information. In order to ensure the effective implementation of Regulation (EC) No 842/2006, it is appropriate to provide for further information to be entered into the system records.
(3) Information on the fluorinated greenhouse gas charge should be included in the system records. Where the fluorinated greenhouse gas charge is unknown, the operator of the fire protection system concerned should ensure that certified personnel determine that charge in order to facilitate the leakage checking.
(4) Before the leakage check is carried out, certified personnel should carefully go through the information contained in the system records to determine any previous issues and consult previous reports.
(5) In order to ensure an efficient leakage control, the leakage checks should focus on those parts of the fire protection system which are most likely to leak.
(6) Where there is a presumption of a leakage, it should be followed up by a check to identify and repair it.
(7) Defective installation of new systems constitutes a significant risk of leakage. Therefore, newly installed systems should be checked for leakage immediately after they have been put into service.
(8) In order to ensure the effectiveness of the repair to the system, the follow up check provided for in Regulation (EC) No 842/2006 should focus on the parts of the system where leakage has been detected and on the adjacent parts.
(9) The measures provided for in this Regulation are in accordance with the opinion of the Committee established by Article 18(1) of Regulation (EC) No 2037/2000 of the European Parliament and of the Council [2],
HAS ADOPTED THIS REGULATION:
Article 1
Subject matter and scope
This Regulation establishes, pursuant to Regulation (EC) No 842/2006, the standard leakage checking requirements for working and temporarily out of operation stationary systems consisting of one or more interconnected containers including associated parts installed in response to a specific fire risk in a defined space, hereinafter "fire protection systems".
This Regulation shall apply to fire protection systems containing 3 kg or more of fluorinated greenhouse gases.
Article 2
System records
1. The operator shall indicate his name, postal address and telephone number in the records referred to in Article 3(6) of Regulation (EC) No 842/2006, hereinafter "system records".
2. The fluorinated greenhouse gas charge for a fire protection system shall be indicated in the system records.
3. Where the fluorinated greenhouse gas charge for a fire protection system is not indicated in the manufacturer's technical specifications or on the label of that system, the operator shall ensure that it is determined by certified personnel.
Article 3
Checking system records
1. Before carrying out leakage checks, certified personnel shall check the system records.
2. Special attention shall be paid to relevant information on any repeating issues or problem areas.
Article 4
Visual and manual checks
1. To identify damage and signs of leakage, certified personnel shall carry out visual checks of operating controls, containers, components and connections which are under pressure.
2. Any presumption of fluorinated greenhouse gas leakage in the fire protection system shall be checked by certified personnel.
3. One or more of the following situations shall constitute a presumption of leakage:
(a) a fixed leakage detection system indicates leakage;
(b) a container shows a loss in pressure, adjusted for temperature, of more than 10 %;
(c) a container shows a loss in extinguishant quantity of more than 5 %;
(d) other signs indicating charge loss.
4. Pressure gauges and weight-monitoring devices shall be checked once every 12 months to ensure their proper functioning.
Article 5
Repair of leakage
1. The operator shall ensure that a repair or a replacement is carried out by personnel certified to undertake that specific activity.
2. The operator shall ensure that a leakage test is carried out prior to recharging.
Article 6
Follow-up check
Certified personnel shall, when carrying out the follow-up check referred to in the second subparagraph of Article 3(2) of Regulation (EC) No 842/2006, focus on those areas where leakages have been found and repaired as well as on adjacent areas in cases where stress has been applied during the repair.
Article 7
Requirements for newly commissioned systems
Newly installed systems shall be checked for leakage immediately after they have been put into service.
Article 8
Entry into force
This Regulation shall enter into force on the 20th day following its publication in the Official Journal of the European Union.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Done at Brussels, 18 December 2007.
For the Commission
Stavros Dimas
Member of the Commission
[1] OJ L 161, 14.6.2006, p. 1.
[2] OJ L 244, 29.9.2000, p. 1. Regulation as last amended by Commission Regulation (EC) No 899/2007 (OJ L 196, 28.7.2007, p. 24).
--------------------------------------------------
| Top |
托管标准,您可以接收以下服务:
1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;
2 随时在标准托管页面中查看到该条标准的最新状态;
3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;
4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;
5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;
6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;
标准资讯点击排行榜 全部
资讯标题点击
[[ n.title ]] [[ n.read ]]大连标准化公共服务平台
版权:大连标准化研究院有限公司
地址:大连市中山区高原街56号
电话:0411-82740851