| 3.12.2010 | EN | Official Journal of the European Union | L 317/42 |
COMMISSION DECISION
of 2 December 2010
establishing the classes of reaction-to-fire performance for certain construction products as regards fibrous gypsum plaster casts
(notified under document C(2010) 392)
(Text with EEA relevance)
(2010/738/EU)
THE EUROPEAN COMMISSION,
Having regard to the Treaty on the Functioning of the European Union,
Having regard to Council Directive 89/106/EEC of 21 December 1988, on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products (1), and in particular Article 20(2)(a) thereof,
After consulting the Standing Committee on Construction,
Whereas:
| (1) | Directive 89/106/EEC envisages that in order to take account of different levels of protection for the construction works at national, regional or local levels, it may be necessary to establish in the interpretative documents classes corresponding to the performance of products in respect of each essential requirement. Those documents have been published as the ‘楥ommunication of the Commission with regard to the interpretative documents of Directive 89/106/EEC (2)‘� |
| (2) | With respect of the essential requirement of safety in the event of fire, interpretative document No 2 lists a number of interrelated measures which together define the fire safety strategy to be variously developed in the Member States. |
| (3) | Interpretative document No 2 identifies one of those measures as the limitation of the generation and spread of fire and smoke within a given area by limiting the potential of construction products to contribute to the full development of a fire. |
| (4) | The level of that limitation may be expressed only in terms of the different levels of reaction-to-fire performance of the products in their end-use application. |
| (5) | By way of a harmonised solution, a system of classes was adopted in Commission Decision 2000/147/EC of 8 February 2000 implementing Council Directive 89/106/EEC as regards the classification of the reaction to fire performance of construction products (3). |
| (6) | In the case of fibrous gypsum plaster casts it is necessary to use the classification established in Decision 2000/147/EC. |
| (7) | The reaction-to-fire performance of many construction products and/or materials, within the classification provided for in Decision 2000/147/EC, is well established and sufficiently well known to fire regulators in Member States that they do not require testing for this particular performance characteristic, |
HAS ADOPTED THIS DECISION:
Article 1
The construction products and/or materials which satisfy all the requirements of the performance characteristic ‘榬eaction-to-fire‘�without need for further testing are set out in the Annex.
Article 2
The specific classes to be applied to different construction products and/or materials, within the reaction-to-fire classification adopted in Decision 2000/147/EC, are set out in the Annex to this Decision.
Article 3
Products shall be considered in relation to their end-use application, where relevant.
Article 4
This Decision is addressed to the Member States.
Done at Brussels, 2 December 2010.
For the Commission
Antonio TAJANI
Vice-President
(1) OJ L 40, 11.2.1989, p. 12.
(3) OJ L 50, 23.2.2000, p. 14.
ANNEX
The table set out in this Annex lists construction products and/or materials which satisfy all of the requirements for the performance characteristic reaction-to-fire without need for testing.
Table
Classes of reaction-to-fire performance for fibrous gypsum plaster casts reinforced with sisal fibres or jute fibres
| Product | Product detail | Minimum density (kg/m3) | Class (1) |
| Fibrous gypsum plaster casts | Product according to EN 13815, made by casting gypsum plaster mixed with water, reinforced by uniformly dispersed sisal or jute fibres at the rate of no more than 2,5 % by mass. | 1 000 | A1 |
(1) Class as provided for in Table 1 of the Annex to Decision 2000/147/EC.
托管标准,您可以接收以下服务:
1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;
2 随时在标准托管页面中查看到该条标准的最新状态;
3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;
4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;
5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;
6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;
标准资讯点击排行榜 全部
资讯标题点击
[[ n.title ]] [[ n.read ]]大连标准化公共服务平台
版权:大连标准化研究院有限公司
地址:大连市中山区高原街56号
电话:0411-82740851