委员会条例(EU) No 347/2010,就不带集成式镇流器荧光灯、高强度气体放电灯以及使此类灯工作的镇流器和照明设备的生态设计要求,修订委员会条例(EC) No 245/2009

技术法规类型:欧盟Eurlex法规 来源:tbtmap

EURLEX ID:32010R0347

OJ编号:OJ L 104, 24.4.2010, p. 20-28

中文标题:委员会条例(EU) No 347/2010,就不带集成式镇流器荧光灯、高强度气体放电灯以及使此类灯工作的镇流器和照明设备的生态设计要求,修订委员会条例(EC) No 245/2009

原文标题:Commission Regulation (EU) No 347/2010 of 21 April 2010 amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps (Text with EEA relevance)

分类:13.30.99_统一法的其它部分;12.10.20_合理利用与节约能源

文件类型:二级立法 Regulation|条例

生效日期:2010-04-25

废止日期:2058-12-31

法规全文:查看欧盟官方文件

EUR-Lex - 32010R0347 - EN
?

32010R0347


Title and reference

Commission Regulation (EU) No 347/2010 of 21 April 2010 amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps (Text with EEA relevance)

?OJ L 104, 24.4.2010, p. 20–28 (BG, ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, MT, NL, PL, PT, RO, SK, SL, FI, SV)

?BG?CS?DA?DE?EL?EN?ES?ET?FI?FR?HU?IT?LT?LV?MT?NL?PL?PT?RO?SK?SL?SV

Text

BG ES CS DA DE ET EL EN FR GA IT LV LT HU MT NL PL PT RO SK SL FI SV
html html html html html html html html html ? html html html html html html html html html html html html html
pdf pdf pdf pdf pdf pdf pdf pdf pdf ? pdf pdf pdf pdf pdf pdf pdf pdf pdf pdf pdf pdf pdf
tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff

Dates

    of document: 21/04/2010
    of effect: 25/04/2010; Entry into force Date pub. + 1 See Art 2
    of effect: 13/04/2010; Implementation See Art 2
    end of validity: 99/99/9999

Classifications

Miscellaneous information

  • Author:
    European Commission
  • Form:
    Regulation
  • Additional information:
    EEA relevance

Relationship between documents

Text

Bilingual display: BG CS DA DE EL EN ES ET FI FR HU IT LT LV MT NL PL PT RO SK SL SV

Commission Regulation (EU) No 347/2010

of 21 April 2010

amending Commission Regulation (EC) No 245/2009 as regards the ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps

(Text with EEA relevance)

THE EUROPEAN COMMISSION,

Having regard to the Treaty on the Functioning of the European Union,

Having regard to Directive 2009/125/EC of the European Parliament and of the Council of 21 October 2009 establishing a framework for the setting of ecodesign requirements for energy-related products [1], and in particular Article 15(1) thereof,

After consulting the Ecodesign Consultation Forum,

Whereas:

(1) After the adoption of Commission Regulation (EC) No 245/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for fluorescent lamps without integrated ballast, for high intensity discharge lamps, and for ballasts and luminaires able to operate such lamps, and repealing Directive 2000/55/EC of the European Parliament and of the Council [2], it appeared that certain provisions of that Regulation should be amended in order to avoid unintended impacts on the availability and performance of the products covered by that Regulation.

(2) In addition, it is necessary to improve coherence, as regards the requirements on product information, between on the one hand Regulation (EC) No 245/2009 and on the other hand Commission Regulation (EC) No 244/2009 of 18 March 2009 implementing Directive 2005/32/EC of the European Parliament and of the Council with regard to ecodesign requirements for non-directional household lamps [3].

(3) The measures provided for in this Regulation are in accordance with the opinion of the Committee established by Article 19(1) of Directive 2009/125/EC,

HAS ADOPTED THIS REGULATION:

Article 1

Amendments to Regulation (EC) No 245/2009

Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as set out in the Annex to this Regulation.

Article 2

Entry into force

This Regulation shall enter into force on the first day following its publication in the Official Journal of the European Union.

It shall apply from 13 April 2010.

This Regulation shall be binding in its entirety and directly applicable in all Member States.

Done at Brussels, 21 April 2010.

For the Commission

The President

José Manuel Barroso

[1] OJ L 285, 31.10.2009, p. 10.

[2] OJ L 76, 24.3.2009, p. 17.

[3] OJ L 76, 24.3.2009, p. 3.

--------------------------------------------------

ANNEX

Amendments in Annexes I, II, III and IV to Regulation (EC) No 245/2009

Annexes I, II, III and IV to Regulation (EC) No 245/2009 are amended as follows:

1. Annex I is amended as follows:

(a) the title is replaced by the following:

"Exemptions";

(b) the introductory sentence in point 1 is replaced by the following:

"The following lamps shall be exempt from the provisions of Annex III, provided that the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC states which of the technical parameters listed hereunder provide(s) a basis for their exemption:";

(c) points 1(c) and 1(d) are replaced by the following:

"(c) blended high intensity discharge lamps having:

- 6 % or more of total radiation of the range 250-780 nm in the range of 250-400 nm; and

- 11 % or more of total radiation of the range 250-780 nm in the range of 630-780 nm; and

- 5 % or more of total radiation of the range 250-780 nm in the range of 640-700 nm;

(d) blended high intensity discharge lamps having:

- the peak of the radiation between 315-400 nm (UVA) or 280-315 nm (UVB);";

(d) point 2 is replaced by the following:

"2. The following products shall be exempt from the provisions of Annex III, provided that in all forms of product information it is stated that they are not intended for general lighting use within the meaning of this Regulation, or that they are intended for use in applications listed in points (b) to (e):

(a) products intended for use in applications other than general lighting and products incorporated into products which do not provide a general lighting function;

(b) lamps covered by the requirements of Directives 94/9/EC of the European Parliament and of the Council [1] or Directive 1999/92/EC of the European Parliament and of the Council [2];

(c) emergency lighting luminaires and emergency sign luminaires within the meaning of Directive 2006/95/EC of the European Parliament and of the Council [3].

(d) ballasts intended for use in luminaires defined in paragraph (c) and designed to operate lamps in emergency conditions;

(e) luminaires covered by the requirements of Directive 94/9/EC, Directive 1999/92/EC, Directive 2006/42/EC of the European Parliament and of the Council [4], Council Directive 93/42/EEC [5], Council Directive 88/378/EEC [6] and luminaires integrated into equipment covered by these requirements.

The intended purpose shall be stated for each product in the product information, and the technical documentation file drawn up for the purposes of conformity assessment pursuant to Article 8 of Directive 2009/125/EC shall list the technical parameters that make the product design specific for the stated intended purpose.

2. Annex II is amended as follows:

(a) the first sentence is deleted;

(b) The following sentence is added to point 1(c):

"For the purposes of Table 6 in Annex III, the LSF shall be measured in high frequency operating mode with a switching cycle of 11h/1h."

(c) The following point (o) is added to point 3:

"(o) "Blended lamp" means a lamp containing a mercury vapour lamp and an incandescent lamp filament connected in series in the same bulb."

3. Annex III is amended as follows:

(a) The following paragraph is added before Table 1:

"Spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) shall comply with the requirements set out in Table 5 for T9 circular lamps."

(b) Table 2 is replaced by the following:

"Table 2

Rated minimum efficacy values for single capped fluorescent lamps working on electromagnetic and electronic ballast

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

Small single parallel tube, lamp cap G23 (2 pin) or 2G7 (4 pin) | Double parallel tubes, lamp cap G24d (2 pin) or G24q (4 pin) | Triple parallel tubes, lamp cap GX24d (2 pin) or GX24q (4 pin) |

Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value | Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value | Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value |

5 | 48 | 10 | 60 | 13 | 62 |

7 | 57 | 13 | 69 | 18 | 67 |

9 | 67 | 18 | 67 | 26 | 66 |

11 | 76 | 26 | 66 | |

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

4 legs in one plane, lamp cap 2G10 (4 pin) | Long single parallel tube, lamp cap 2G11 (4 pin) | |

Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value | Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value | |

18 | 61 | 18 | 67 | |

24 | 71 | 24 | 75 |

36 | 78 | 34 | 82 |

| 36 | 81" |

(c) Table 3 is replaced by the following:

"Table 3

Rated minimum efficacy values for single capped fluorescent lamps, working only on electronic ballast

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

+++++ TIFF +++++

Triple parallel tubes, lamp cap GX24q (4 pin) | Four parallel tubes, lamp cap GX24q (4 pin) | Long single parallel tube, lamp cap 2G11 (4 pin) |

Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value | Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value | Nominal wattage (W) | Rated luminous efficacy (lm/W), 100 h initial value |

32 | 75 | 57 | 75 | 40 | 83 |

42 | 74 | 70 | 74 | 55 | 82 |

57 | 75 | | 80 | 75 |

70 | 74" | |

(d) Table 6 is replaced by the following:

"Table 6

Deduction percentages for rated minimum efficacy values for fluorescent lamps with high colour temperature and/or high colour rendering and/or second lamp envelope and/or long life

Lamp parameter | Deduction from luminous efficacy at 25 °C |

Tc ≥ 5000 K | –10 % |

95 ≥ Ra > 90 | –20 % |

Ra > 95 | –30 % |

Second lamp envelope | –10 % |

Lamp Survival Factor ≥ 0,50 after 40000 burning hours | –5 %" |

(e) In Annex III.1.1.B, the sentence

"The corrections defined for the first stage (Table 6) shall continue to apply"

is replaced by

"The corrections (Table 6) and the specific requirements for spiral-shaped double capped fluorescent lamps defined for the first stage shall continue to apply.";

(f) The title of Table 7 is replaced by the following:

"Table 7

Rated minimum efficacy values for high pressure sodium lamps with Ra ≤ 60";

(g) The title of Table 8 is replaced by the following:

"Table 8

Rated minimum efficacy values for Metal Halide Lamps with Ra ≤ 80 and for high pressure sodium lamps with Ra > 60"

(h) The second paragraph of Annex III.1.1.C is replaced by the following:

"Fluorescent lamps without integrated ballast shall be able to operate with ballasts of energy efficiency class A2 or more efficient ballasts in accordance with point 2.2 of Annex III. In addition they may also operate with ballasts of less efficient classes than A2."

(i) Table 11 is replaced by the following:

"Table 11

Lamp lumen maintenance factors for single and double capped fluorescent lamps — Stage 2

Lamp lumen maintenance factor | Burning hours |

Lamp types | 2000 | 4000 | 8000 | 16000 |

Double-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,95 | 0,92 | 0,90 | — |

T8 Double-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,96 | 0,92 | 0,91 | 0,90 |

Other Double-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,95 | 0,92 | 0,90 | 0,90 |

Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) | 0,80 | 0,74 | — | — |

0,72 at 5000 burning hours |

Circular Single-Capped Fluorescent lamps operating on high frequency ballasts | 0,85 | 0,83 | 0,80 | — |

0,75 at 12000 burning hours |

Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,85 | 0,78 | 0,75 | — |

Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,90 | 0,84 | 0,81 | 0,78" |

(j) The following introductory phrase and Table 11a is added after Table 11:

"The following cumulative deductions shall be applied to the values in Table 11:

Table 11a

Deduction percentages for fluorescent lamp lumen maintenance requirements

Lamp parameter | Deduction from lamp lumen maintenance requirement |

Lamps with 95 ≥ Ra > 90 | At burning hours ≤ 8000 h: – 5 % At burning hours > 8000 h: – 10 % |

Lamps with Ra > 95 | At burning hours ≤ 4000 h: – 10 % At burning hours > 4000 h: – 15 % |

Lamps with a colour temperature ≥ 5000 K | –10 %" |

(k) Table 12 is replaced by the following:

"Table 12

Lamp survival factors for single and double capped fluorescent lamps — Stage 2

Lamp survival factor | Burning hours |

Lamp types | 2000 | 4000 | 8000 | 16000 |

Double-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,99 | 0,97 | 0,90 | — |

Double-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,99 | 0,97 | 0,92 | 0,90 |

Circular Single-Capped Fluorescent lamps operating on non-high frequency ballasts, T8 U-shaped double-capped fluorescent lamps and spiral-shaped double capped fluorescent lamps of all diameters equal to or larger than 16 mm (T5) | 0,98 | 0,77 | — | — |

0,50 at 5000 burning hours |

Circular Single-Capped Fluorescent lamps operating on high frequency ballasts | 0,99 | 0,97 | 0,85 | — |

0,50 at 12000 burning hours |

Other Single-Capped Fluorescent lamps operating on non-high frequency ballasts | 0,98 | 0,90 | 0,50 | — |

Other Single-Capped Fluorescent lamps on high frequency ballast with warmstart | 0,99 | 0,98 | 0,88 | —" |

(l) Table 13 is replaced by the following:

"Table 13

Lamp lumen maintenance factors and lamp survival factors for high pressure sodium lamps — Stage 2

High pressure sodium lamp category and burning hours for measurement | Lamp lumen maintenance factor | Lamp survival factor |

P ≤ 75 W LLMF and LSF measured at 12000 burning hours | Ra ≤ 60 | > 0,80 | > 0,90 |

Ra > 60 | > 0,75 | > 0,75 |

all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast | > 0,75 | > 0,80 |

P > 75 W LLMF and LSF measured at 16000 burning hours | Ra ≤ 60 | > 0,85 | > 0,90 |

Ra > 60 | > 0,70 | > 0,65 |

all retrofit lamps designed to operate on high pressure mercury vapour lamp ballast | > 0,75 | > 0,55 |

The requirements in Table 13 for retrofit lamps designed to operate on high pressure mercury vapour lamp ballast shall be applicable until 6 years after the entry into force of this Regulation.";

(m) Annex III.1.3(i) is replaced by the following:

"(i) Ambient temperature inside the luminaire at which the lamp was designed to maximise its luminous flux. If this temperature is equal to or lower than 0 °C or equal to or higher than 50 °C, it shall be stated that the lamp is not suitable for indoor use at standard room temperatures.";

(n) The following point (j) is added to point 1.3 of Annex III:

"(j) For fluorescent lamps without integrated ballast, the energy efficiency index(es) of ballasts as defined in Table 17 with which the lamp can operate.";

(o) Table 17 is replaced by the following:

"Table 17

Energy efficiency index requirements for non-dimmable ballasts for fluorescent lamps

LAMP DATA | BALLAST EFFICIENCY (Plamp/Pinput) |

Non-dimmable |

Lamp type | Nominal Wattage | ILCOS CODE | Rated/typical wattage | A2 BAT | A2 | A3 | B1 | B2 |

50 Hz | HF |

W | W | W | | | | | |

T8 | 15 | FD-15-E-G13-26/450 | 15 | 13,5 | 87,8 % | 84,4 % | 75,0 % | 67,9 % | 62,0 % |

T8 | 18 | FD-18-E-G13-26/600 | 18 | 16 | 87,7 % | 84,2 % | 76,2 % | 71,3 % | 65,8 % |

T8 | 30 | FD-30-E-G13-26/900 | 30 | 24 | 82,1 % | 77,4 % | 72,7 % | 79,2 % | 75,0 % |

T8 | 36 | FD-36-E-G13-26/1200 | 36 | 32 | 91,4 % | 88,9 % | 84,2 % | 83,4 % | 79,5 % |

T8 | 38 | FD-38-E-G13-26/1050 | 38,5 | 32 | 87,7 % | 84,2 % | 80,0 % | 84,1 % | 80,4 % |

T8 | 58 | FD-58-E-G13-26/1500 | 58 | 50 | 93,0 % | 90,9 % | 84,7 % | 86,1 % | 82,2 % |

T8 | 70 | FD-70-E-G13-26/1800 | 69,5 | 60 | 90,9 % | 88,2 % | 83,3 % | 86,3 % | 83,1 % |

TC-L | 18 | FSD-18-E-2G11 | 18 | 16 | 87,7 % | 84,2 % | 76,2 % | 71,3 % | 65,8 % |

TC-L | 24 | FSD-24-E-2G11 | 24 | 22 | 90,7 % | 88,0 % | 81,5 % | 76,0 % | 71,3 % |

TC-L | 36 | FSD-36-E-2G11 | 36 | 32 | 91,4 % | 88,9 % | 84,2 % | 83,4 % | 79,5 % |

TCF | 18 | FSS-18-E-2G10 | 18 | 16 | 87,7 % | 84,2 % | 76,2 % | 71,3 % | 65,8 % |

TCF | 24 | FSS-24-E-2G10 | 24 | 22 | 90,7 % | 88,0 % | 81,5 % | 76,0 % | 71,3 % |

TCF | 36 | FSS-36-E-2G10 | 36 | 32 | 91,4 % | 88,9 % | 84,2 % | 83,4 % | 79,5 % |

TC-D / DE | 10 | FSQ-10-E-G24q=1 FSQ-10-I-G24d=1 | 10 | 9,5 | 89,4 % | 86,4 % | 73,1 % | 67,9 % | 59,4 % |

TC-D / DE | 13 | FSQ-13-E-G24q=1 FSQ-13-I-G24d=1 | 13 | 12,5 | 91,7 % | 89,3 % | 78,1 % | 72,6 % | 65,0 % |

TC-D / DE | 18 | FSQ-18-E-G24q=2 FSQ-18-I-G24d=2 | 18 | 16,5 | 89,8 % | 86,8 % | 78,6 % | 71,3 % | 65,8 % |

TC-D / DE | 26 | FSQ-26-E-G24q=3 FSQ-26-I-G24d=3 | 26 | 24 | 91,4 % | 88,9 % | 82,8 % | 77,2 % | 72,6 % |

TC-T / TE | 13 | FSM-13-E-GX24q=1 FSM-13-I-GX24d=1 | 13 | 12,5 | 91,7 % | 89,3 % | 78,1 % | 72,6 % | 65,0 % |

TC-T / TE | 18 | FSM-18-E-GX24q=2 FSM-18-I-GX24d=2 | 18 | 16,5 | 89,8 % | 86,8 % | 78,6 % | 71,3 % | 65,8 % |

TC-T / TC-TE | 26 | FSM-26-E-GX24q=3 FSM-26-I-GX24d=3 | 26,5 | 24 | 91,4 % | 88,9 % | 82,8 % | 77,5 % | 73,0 % |

TC-DD / DDE | 10 | FSS-10-E-GR10q FSS-10-L/P/H-GR10q | 10,5 | 9,5 | 86,4 % | 82,6 % | 70,4 % | 68,8 % | 60,5 % |

TC-DD / DDE | 16 | FSS-16-E-GR10q FSS-16-I-GR8 FSS-16-L/P/H-GR10q | 16 | 15 | 87,0 % | 83,3 % | 75,0 % | 72,4 % | 66,1 % |

TC-DD / DDE | 21 | FSS-21-E-GR10q FSS-21-L/P/H-GR10q | 21 | 19,5 | 89,7 % | 86,7 % | 78,0 % | 73,9 % | 68,8 % |

TC-DD / DDE | 28 | FSS-28-E-GR10q FSS-28-I-GR8 FSS-28-L/P/H-GR10q | 28 | 24,5 | 89,1 % | 86,0 % | 80,3 % | 78,2 % | 73,9 % |

TC-DD / DDE | 38 | FSS-38-E-GR10q FSS-38-L/P/H-GR10q | 38,5 | 34,5 | 92,0 % | 89,6 % | 85,2 % | 84,1 % | 80,4 % |

TC | 5 | FSD-5-I-G23 FSD-5-E-2G7 | 5,4 | 5 | 72,7 % | 66,7 % | 58,8 % | 49,3 % | 41,4 % |

TC | 7 | FSD-7-I-G23 FSD-7-E-2G7 | 7,1 | 6,5 | 77,6 % | 72,2 % | 65,0 % | 55,7 % | 47,8 % |

TC | 9 | FSD-9-I-G23 FSD-9-E-2G7 | 8,7 | 8 | 78,0 % | 72,7 % | 66,7 % | 60,3 % | 52,6 % |

TC | 11 | FSD-11-I-G23 FSD-11-E-2G7 | 11,8 | 11 | 83,0 % | 78,6 % | 73,3 % | 66,7 % | 59,6 % |

T5 | 4 | FD-4-E-G5-16/150 | 4,5 | 3,6 | 64,9 % | 58,1 % | 50,0 % | 45,0 % | 37,2 % |

T5 | 6 | FD-6-E-G5-16/225 | 6 | 5,4 | 71,3 % | 65,1 % | 58,1 % | 51,8 % | 43,8 % |

T5 | 8 | FD-8-E-G5-16/300 | 7,1 | 7,5 | 69,9 % | 63,6 % | 58,6 % | 48,9 % | 42,7 % |

T5 | 13 | FD-13-E-G5-16/525 | 13 | 12,8 | 84,2 % | 80,0 % | 75,3 % | 72,6 % | 65,0 % |

T9-C | 22 | FSC-22-E-G10q-29/200 | 22 | 19 | 89,4 % | 86,4 % | 79,2 % | 74,6 % | 69,7 % |

T9-C | 32 | FSC-32-E-G10q-29/300 | 32 | 30 | 88,9 % | 85,7 % | 81,1 % | 80,0 % | 76,0 % |

T9-C | 40 | FSC-40-E-G10q-29/400 | 40 | 32 | 89,5 % | 86,5 % | 82,1 % | 82,6 % | 79,2 % |

T2 | 6 | FDH-6-L/P-W4,3x8,5d-7/220 | | 5 | 72,7 % | 66,7 % | 58,8 % | | |

T2 | 8 | FDH-8-L/P-W4,3x8,5d-7/320 | | 7,8 | 76,5 % | 70,9 % | 65,0 % | | |

T2 | 11 | FDH-11-L/P-W4,3x8,5d-7/420 | | 10,8 | 81,8 % | 77,1 % | 72,0 % | | |

T2 | 13 | FDH-13-L/P-W4,3x8,5d-7/520 | | 13,3 | 84,7 % | 80,6 % | 76,0 % | | |

T2 | 21 | FDH-21-L/P-W4,3x8,5d-7/ | | 21 | 88,9 % | 85,7 % | 79,2 % | | |

T2 | 23 | FDH-23-L/P-W4,3x8,5d-7/ | | 23 | 89,8 % | 86,8 % | 80,7 % | | |

T5-E | 14 | FDH-14-G5-L/P-16/550 | | 13,7 | 84,7 % | 80,6 % | 72,1 % | | |

T5-E | 21 | FDH-21-G5-L/P-16/850 | | 20,7 | 89,3 % | 86,3 % | 79,6 % | | |

T5-E | 24 | FDH-24-G5-L/P-16/550 | | 22,5 | 89,6 % | 86,5 % | 80,4 % | | |

T5-E | 28 | FDH-28-G5-L/P-16/1150 | | 27,8 | 89,8 % | 86,9 % | 81,8 % | | |

T5-E | 35 | FDH-35-G5-L/P-16/1450 | | 34,7 | 91,5 % | 89,0 % | 82,6 % | | |

T5-E | 39 | FDH-39-G5-L/P-16/850 | | 38 | 91,0 % | 88,4 % | 82,6 % | | |

T5-E | 49 | FDH-49-G5-L/P-16/1450 | | 49,3 | 91,6 % | 89,2 % | 84,6 % | | |

T5-E | 54 | FDH-54-G5-L/P-16/1150 | | 53,8 | 92,0 % | 89,7 % | 85,4 % | | |

T5-E | 80 | FDH-80-G5-L/P-16/1150 | | 80 | 93,0 % | 90,9 % | 87,0 % | | |

T5-E | 95 | FDH-95-G5-L/P-16/1150 | | 95 | 92,7 % | 90,5 % | 84,1 % | | |

T5-E | 120 | FDH-120-G5-L/P-16/1450 | | 120 | 92,5 % | 90,2 % | 84,5 % | | |

T5-C | 22 | FSCH-22-L/P-2GX13-16/225 | | 22,3 | 88,1 % | 84,8 % | 78,8 % | | |

T5-C | 40 | FSCH-40-L/P-2GX13-16/300 | | 39,9 | 91,4 % | 88,9 % | 83,3 % | | |

T5-C | 55 | FSCH-55-L/P-2GX13-16/300 | | 55 | 92,4 % | 90,2 % | 84,6 % | | |

T5-C | 60 | FSCH-60-L/P-2GX13-16/375 | | 60 | 93,0 % | 90,9 % | 85,7 % | | |

TC-LE | 40 | FSDH-40-L/P-2G11 | | 40 | 91,4 % | 88,9 % | 83,3 % | | |

TC-LE | 55 | FSDH-55-L/P-2G11 | | 55 | 92,4 % | 90,2 % | 84,6 % | | |

TC-LE | 80 | FSDH-80-L/P-2G11 | | 80 | 93,0 % | 90,9 % | 87,0 % | | |

TC-TE | 32 | FSMH-32-L/P-2GX24q=3 | | 32 | 91,4 % | 88,9 % | 82,1 % | | |

TC-TE | 42 | FSMH-42-L/P-2GX24q=4 | | 43 | 93,5 % | 91,5 % | 86,0 % | | |

TC-TE | 57 | FSM6H-57-L/P-2GX24q=5 FSM8H-57-L/P-2GX24q=5 | | 56 | 91,4 % | 88,9 % | 83,6 % | | |

TC-TE | 70 | FSM6H-70-L/P-2GX24q=6 FSM8H-70-L/P-2GX24q=6 | | 70 | 93,0 % | 90,9 % | 85,4 % | | |

TC-TE | 60 | FSM6H-60-L/P-2G8=1 | | 63 | 92,3 % | 90,0 % | 84,0 % | | |

TC-TE | 62 | FSM8H-62-L/P-2G8=2 | | 62 | 92,2 % | 89,9 % | 83,8 % | | |

TC-TE | 82 | FSM8H-82-L/P-2G8=2 | | 82 | 92,4 % | 90,1 % | 83,7 % | | |

TC-TE | 85 | FSM6H-85-L/P-2G8=1 | | 87 | 92,8 % | 90,6 % | 84,5 % | | |

TC-TE | 120 | FSM6H-120-L/P-2G8=1 FSM8H-120-L/P-2G8=1 | | 122 | 92,6 % | 90,4 % | 84,7 % | | |

TC-DD | 55 | FSSH-55-L/P-GRY10q3 | | 55 | 92,4 % | 90,2 % | 84,6 %" | | |

4. The following paragraph is added after the first paragraph of Annex IV:

"Member States authorities shall use reliable, accurate and reproducible measurement procedures, which take into account the generally recognised state of the art measurement methods, including methods set out in documents the reference numbers of which have been published for that purpose in the Official Journal of the European Union."

[1] OJ L 100, 19.4.1994, p. 1.

[2] OJ L 23, 28.1.2000, p. 57.

[3] OJ L 374, 27.12.2006, p. 10.

[4] OJ L 157, 9.6.2006, p. 24.

[5] OJ L 169, 12.7.1993, p. 1.

[6] OL L 187, 16.7.1988, p. 1."

--------------------------------------------------

Top

托管标准,您可以接收以下服务:

1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;

2 随时在标准托管页面中查看到该条标准的最新状态;

3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;

4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;

5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;

6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;

进入企业标准托管

您可以通过编辑查新模板,批量查询指定标准集的最新情况。我们会通过查询,向您展示您所查询标准的:

1. 准确的标准号及标准名称(我们通过人工智能技术对您提交的标准号进行自动纠正)

2. 标准的最新状态(现行、废止或未发布)

3. 若标准已废止并被新标准替代,会反馈被替代的标准

4. 若您已托管此标准,便可以实时跟踪这个标准的最新状态

标准查新 模板下载

您可以在这里检索全球超过140万条标准,支持上百个国内国际标准组织的标准查询。您也可以在这里检索国内各类国家、部委和地方的法律法规。

更多标准子库在持续建设中。

标准检索

标准资讯点击排行榜 全部

资讯标题点击

[[ n.title ]] [[ n.read ]]

大连标准化公共服务平台

版权:大连标准化研究院有限公司

地址:大连市中山区高原街56号

电话:0411-82740851

大连标准