委员会实施条例(EU) No 1038/2014,某些物品在组合法编码中的分类

技术法规类型:欧盟Eurlex法规 来源:tbtmap

EURLEX ID:32014R1038

OJ编号:OJ L 287, 1.10.2014, p. 14-19

中文标题:委员会实施条例(EU) No 1038/2014,某些物品在组合法编码中的分类

原文标题:Commission Implementing Regulation (EU) No 1038/2014 of 25 September 2014 concerning the classification of certain goods in the Combined Nomenclature

分类:02.30.10_关税分类

文件类型:二级立法 Regulation|条例

生效日期:2014-10-21

废止日期:2058-12-31

法规全文:查看欧盟官方文件

L_2014287EN.01001401.xml

1.10.2014   

EN

Official Journal of the European Union

L 287/14


COMMISSION IMPLEMENTING REGULATION (EU) No 1038/2014

of 25 September 2014

concerning the classification of certain goods in the Combined Nomenclature

THE EUROPEAN COMMISSION,

Having regard to the Treaty on the Functioning of the European Union,

Having regard to Council Regulation (EEC) No 2658/87 of 23 July 1987 on the tariff and statistical nomenclature and on the Common Customs Tariff (1), and in particular Article 9(1)(a) thereof,

Whereas:

(1)

In order to ensure uniform application of the Combined Nomenclature annexed to Regulation (EEC) No 2658/87, it is necessary to adopt measures concerning the classification of the goods referred to in the Annex to this Regulation.

(2)

Regulation (EEC) No 2658/87 has laid down the general rules for the interpretation of the Combined Nomenclature. Those rules apply also to any other nomenclature which is wholly or partly based on it or which adds any additional subdivision to it and which is established by specific provisions of the Union, with a view to the application of tariff and other measures relating to trade in goods.

(3)

Pursuant to those general rules, the goods described in column (1) of the table set out in the Annex should be classified under the CN codes indicated in column (2), by virtue of the reasons set out in column (3) of that table.

(4)

It is appropriate to provide that binding tariff information issued in respect of the goods concerned by this Regulation which does not conform to this Regulation may, for a certain period, continue to be invoked by the holder in accordance with Article 12(6) of Council Regulation (EEC) No 2913/92 (2). That period should be set at three months.

(5)

The measures provided for in this Regulation are in accordance with the opinion of the Customs Code Committee,

HAS ADOPTED THIS REGULATION:

Article 1

The goods described in column (1) of the table set out in the Annex shall be classified within the Combined Nomenclature under the CN codes indicated in column (2) of that table.

Article 2

Binding tariff information which does not conform to this Regulation may continue to be invoked in accordance with Article 12(6) of Regulation (EEC) No 2913/92 for a period of three months from the date of entry into force of this Regulation.

Article 3

This Regulation shall enter into force on the twentieth day following that of its publication in the Official Journal of the European Union.

This Regulation shall be binding in its entirety and directly applicable in all Member States.

Done at Brussels, 25 September 2014.

For the Commission,

On behalf of the President,

Heinz ZOUREK

Director-General for Taxation and Customs Union


(1)  OJ L 256, 7.9.1987, p. 1.

(2)  Council Regulation (EEC) No 2913/92 of 12 October 1992 establishing the Community Customs Code (OJ L 302, 19.10.1992, p. 1).


ANNEX

Description of the goods

Classification

(CN code)

Reasons

(1)

(2)

(3)

1.

A plastic tube with a length of 142 cm with a plastic balloon at one end (so-called ‘balloon catheter’).

The proximal segment of the catheter has a diameter of 0,63 mm and is made of hypotube material and coated with polytetrafluorethylene (PTFE).

The distal segment of the catheter has a diameter in a range from 0,79 to 1,02 mm and is made of polyether bloc amide (PEBA) material and coated with hydrophilic material.

The balloon has a length of 6 to 27 mm and a diameter of 2 to 5 mm.

The tube has a Luer connection, an atraumatic (flexible) tip and 2 golden marker bands.

The Luer connection makes it possible to connect the tube to an inflating device which is used to inflate the balloon.

The atraumatic tip is used to move the catheter via a vein up through the body into the coronary artery. When the catheter is on the right place in the coronary artery, the balloon is inflated so that the fatty deposits (atherosclerotic plaque) are pressed against the wall of the vein. By compressing the plaque, the inside diameter of the vein increases.

The marker bands make it possible to locate the exact position of the atraumatic tip in the body.

The balloon catheter is removed from the body and discarded after treatment.

The article is presented in packaging and is sterilised.

 (1)See image 1

9018 39 00

Classification is determined by general rules 1 and 6 for the interpretation of the Combined Nomenclature, and by the wording of CN codes 9018 and 9018 39 00.

Due to its objective characteristics, namely the combination of the balloon, the atraumatic tip, the golden marker bands and the Luer connection, the tube can, upon presentation, be identified as an instrument or appliance of Chapter 90, used in medical sciences.

Classification under heading 9021 is excluded as the tube is not implanted in the body to compensate for a defect or disability but it is removed after treatment.

The product is therefore to be classified under CN code 9018 39 00 as catheters (see also the Harmonized System Explanatory Notes (HSEN) to heading 9018, Group (I)).

2.

A plastic curved tube (so-called ‘guide catheter’) with an inner diameter ranging from 1,47 mm to 2,29 mm and a length of 100 cm with a radiopaque marker and an atraumatic (flexible) tip.

The article comprises a double interlock knit flat section of stainless steel, encapsulated in plastic material (PEBA, polyphthalamide (PPA), Nylon) and it has a lubricant coating applied to the silicon inner surface of the guide catheter.

The guide catheter enables access to the coronary artery through a vein. Other appliances can be directed by this guide catheter to the artery.

The radiopaque marker makes it possible to locate the exact position of the atraumatic tip in the body.

The guide catheter is removed from the body and discarded after treatment.

The article is presented in packaging and is sterilised.

 (1)See image 2

9018 39 00

Classification is determined by general rules 1 and 6 for the interpretation of the Combined Nomenclature, and by the wording of CN codes 9018 and 9018 39 00.

Due to its objective characteristics, namely the combination of the curve, the radiopaque marker, the atraumatic tip and the lubricant coating, the tube can, upon presentation, be identified as an instrument or appliance of Chapter 90, used in medical sciences.

Classification under heading 9021 is excluded as the tube is not implanted in the body to compensate for a defect or disability but it is removed after treatment.

The product is therefore to be classified under CN code 9018 39 00 as catheters (see also the HSEN to heading 9018, Group (I)).

3.

A flexible metal wire (so-called ‘guide wire’) with a diameter of 0,35 mm, a length ranging from 180-300 cm, two radiopaque markers and a rounded tip.

The wire is made of a metal alloy for biomedical use, with a proximal coating of PTFE and a distal coating of silicone or hydrophilic material.

The radiopaque markers make it possible to locate the exact position of the wire in the body.

The wire is used for guiding and positioning devices for interventions in the coronary artery.

The guide wire is removed from the body and discarded after treatment.

The article is presented in packaging and is sterilised.

 (1)See image 3

9018 39 00

Classification is determined by general rules 1 and 6 for the interpretation of the Combined Nomenclature, and by the wording of CN codes 9018 and 9018 39 00.

Due to its objective characteristics, namely the combination of the design and the radiopaque markers, the wire can, upon presentation, be identified as an instrument or appliance of Chapter 90, used in medical sciences.

Classification under heading 9021 is excluded as the wire is not implanted in the body to compensate for a defect or disability but it is removed after treatment.

The product is therefore to be classified under CN code 9018 39 00 as wire guides (see also the HSEN to heading 9018 Group (I)).

4.

A hand-operated inflation device made of high-strength polycarbonate, equipped with a manometer and a volume scale. It has a high pressure hose connection (Luer-type) and can inflate, with precise pressure adjustments, up to 20 atmospheres (atm).

The device is to be used in a medical environment for the inflation and deflation of balloon catheters.

The manometer is used for monitoring the pressure inside the balloon catheter when inflating or deflating and during surgery.

The volume scale indicates the amount of liquid (maximum 20 ml) that is, by means of pressure, inserted into the catheter and also the amount of liquid that flows back freely as the balloon deflates.

The Luer connection makes it possible to connect the inflation device to the balloon catheter.

The device is for single patient use only and is discarded after treatment.

The article is presented in packaging and is sterilised.

 (1)See image 4

9018 90 84

Classification is determined by general rules 1 and 6 for the interpretation of the Combined Nomenclature and by the wording of CN codes 9018, 9018 90 and 9018 90 84.

As a small amount of liquid is inserted into the catheter by means of pressure, but then flows back freely, the device does not raise or otherwise continuously displace volumes of liquids (see the HSEN to heading 8413, first paragraph). Consequently, classification under heading 8413 as pumps for liquids is excluded.

Due to its objective characteristics, namely the combination of the design, the precise pressure adjustments, the small amount of liquid used and the Luer-type connection, the article can, upon presentation, be identified as an instrument or appliance of Chapter 90, used in medical sciences (see also the HSEN to heading 9018, fifth paragraph).

Classification under heading 9021 is excluded as the article is not worn, carried or implanted in the body to compensate for a defect or disability.

The product is therefore to be classified under CN code 9018 90 84 as other instruments and appliances used in medical, surgical, dental or veterinary sciences.

Image 1

Image

Image 2

Image

Image 3

Image

Image 4

Image


(1)  The images are purely for information.


附件:

P020171219592195762807.pdf

托管标准,您可以接收以下服务:

1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;

2 随时在标准托管页面中查看到该条标准的最新状态;

3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;

4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;

5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;

6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;

进入企业标准托管

您可以通过编辑查新模板,批量查询指定标准集的最新情况。我们会通过查询,向您展示您所查询标准的:

1. 准确的标准号及标准名称(我们通过人工智能技术对您提交的标准号进行自动纠正)

2. 标准的最新状态(现行、废止或未发布)

3. 若标准已废止并被新标准替代,会反馈被替代的标准

4. 若您已托管此标准,便可以实时跟踪这个标准的最新状态

标准查新 模板下载

您可以在这里检索全球超过140万条标准,支持上百个国内国际标准组织的标准查询。您也可以在这里检索国内各类国家、部委和地方的法律法规。

更多标准子库在持续建设中。

标准检索

标准资讯点击排行榜 全部

资讯标题点击

[[ n.title ]] [[ n.read ]]

大连标准化公共服务平台

版权:大连标准化研究院有限公司

地址:大连市中山区高原街56号

电话:0411-82740851

大连标准