委员会决定2005/823/EC,就屋顶和屋顶覆盖物的外部消防性能的分类修订实施理事会指令89/106/EEC的决定2001/671/EC(通报文件号C(2005) 4437)(内容与EEA相关)
技术法规类型:欧盟Eurlex法规 来源:tbtmap
EURLEX ID:32005D0823
OJ编号:OJ L 307, 25.11.2005, p. 53-54
中文标题:委员会决定2005/823/EC,就屋顶和屋顶覆盖物的外部消防性能的分类修订实施理事会指令89/106/EEC的决定2001/671/EC(通报文件号C(2005) 4437)(内容与EEA相关)
原文标题:2005/823/EC: Commission Decision of 22 November 2005 amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2005) 4437) (Text with EEA relevance)
分类:13.30.99_统一法的其它部分
文件类型:二级立法 Decision|决定
废止日期:2058-12-31
法规全文:查看欧盟官方文件
32005D0823
Title and reference
2005/823/EC: Commission Decision of 22 November 2005 amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings (notified under document number C(2005) 4437) (Text with EEA relevance)
?OJ L 307, 25.11.2005, p. 53–54 (ES, CS, DA, DE, ET, EL, EN, FR, IT, LV, LT, HU, NL, PL, PT, SK, SL, FI, SV)
?OJ L 349M , 12.12.2006, p. 615–616 (MT)
?Special edition in Bulgarian: Chapter 13 Volume 49 P. 268 - 269
?Special edition in Romanian: Chapter 13 Volume 49 P. 268 - 269
?CS?DA?DE?EL?EN?ES?ET?FI?FR?HU?IT?LT?LV?NL?PL?PT?SK?SL?SV
Text
| BG | ES | CS | DA | DE | ET | EL | EN | FR | GA | IT | LV | LT | HU | MT | NL | PL | PT | RO | SK | SL | FI | SV |
| ? | html | html | html | html | html | html | html | html | ? | html | html | html | html | ? | html | html | html | ? | html | html | html | html |
| ? | ? | |||||||||||||||||||||
| tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff | tiff |
Authentic language
- The official languages, Other than Community language, Icelandic, Norwegian
Dates
- of document: 22/11/2005
of notification: 00/00/0000
of effect: 00/00/0000; Entry into force Date notif.
end of validity: 99/99/9999
Classifications
- EUROVOC descriptor:
building materials
technical regulations
fire protection
product safety - Directory code:
13.30.99.00 Industrial policy and internal market / Internal market: approximation of laws / Other sectors for approximation of laws
- Subject matter:
Internal market, Approximation of laws, Technical barriers
Miscellaneous information
- Author:
European Commission - Form:
Decision - Addressee:
Member States of the Community - Additional information:
Extended to the EEA by 22006D0084
Relationship between documents
- Treaty:
European Community - Legal basis:
31989L0106 -A20P2PT(A)
- Select all documents based on this document
- Amendment to:
32001D0671 Amendment Amendment Annex 1 from /T/DATN
- Select all documents mentioning this document
Text
| Bilingual display: BG CS DA DE EL EN ES ET FI FR HU IT LT LV NL PL PT RO SK SL SV |
Commission Decision
of 22 November 2005
amending Decision 2001/671/EC implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings
(notified under document number C(2005) 4437)
(Text with EEA relevance)
(2005/823/EC)
THE COMMISSION OF THE EUROPEAN COMMUNITIES,
Having regard to the Treaty establishing the European Community,
Having regard to Council Directive 89/106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of the Member States relating to construction products [1], and in particular Article 20(2)(a) thereof,
Whereas:
(1) Commission Decision 2001/671/EC of 21 August 2001 implementing Council Directive 89/106/EEC as regards the classification of the external fire performance of roofs and roof coverings [2] established a classification system for the external fire performance of roofs and roof coverings.
(2) Following a review additional classes should be introduced to accommodate the regulatory needs of Ireland and the United Kingdom.
(3) Decision 2001/671/EC should therefore be amended accordingly.
(4) The measures provided for in this Decision are in accordance with the opinion of the Standing Committee on Construction,
HAS ADOPTED THIS DECISION:
Article 1
The Annex to Decision 2001/671/EC is amended in accordance with the Annex to this Decision.
Article 2
This Decision is addressed to the Member States.
Done at Brussels, 22 November 2005.
For the Commission
Günter Verheugen
Vice-President
[1] OJ L 40, 11.2.1989, p. 12. Directive as last amended by Regulation (EC) No 1882/2003 of the European Parliament and of the Council (OJ L 284, 31.10.2003, p. 1).
[2] OJ L 235, 4.9.2001, p. 20.
--------------------------------------------------
ANNEX
The Annex to Decision 2001/671/EC is amended as follows.
1. the section entitled PREAMBLE is amended as follows:
(a) the first paragraph is replaced by "ENV 1187:2002 and subsequently upgraded versions shall be applied. The upgraded version shall include, inter alia, new revisions/amendments of the ENV or the EN version of this standard";
(b) in the second paragraph "CR 1187:2001" is replaced by "ENV 1187:2002" and in the second line, "three" is replaced by "four";
2. the section entitled "SYMBOLS" is amended as follows:
(a) in the first line, the word "three" is replaced by "four";
(b) all references to "CR 1187:2001" shall be replaced by "ENV 1187:2002";
(c) "— ENV 1187:2002 test 4: XROOF (t4) where t4 = burning brand + wind + supplementary radiant heat" is inserted after the line for CR 1187:2001 test 3;
3. in the table the following rows are added:
* Attention shall be drawn to dripping from the underside of the specimen, any mechanical failure and any development of holes by adding a suffix "x" to the designation to denote that one or more of these took place during the test. In addition, depending upon inclination of the product during the test, the letters EXT.F will be added to indicate "flat or horizontal" and EXT.S will be added to indicate "inclined"."
Test method | Class | Classification criteria |
"ENV 1187:2002 test 4 | BROOF (t4) | All of the following conditions must be satisfied: No penetration of roof system within 1 hourIn the preliminary test, after withdrawal of test flame, specimens burn for < 5 minutesIn the preliminary test, flame spread < 0.38 m across the region of burning |
CROOF (t4) | All of the following conditions must be satisfied: No penetration of roof system within 30 minutesIn the preliminary test, after withdrawal of test flame, specimens burn for < 5 minutesIn the preliminary test, flame spread < 0.38 m across the region of burning |
DROOF (t4) | All of the following conditions must be satisfied: Roof system is penetrated within 30 minutes but is not penetrated in the preliminary flame testIn the preliminary test, after withdrawal of test flame, specimens burn for < 5 minutesIn the preliminary test, flame spread < 0.38 m across the region of burning |
EROOF (t4) | All of the following conditions must be satisfied: Roof system is penetrated within 30 minutes but is not penetrated in the preliminary flame testFlame spread is not controlled |
FROOF (t4) | No performance determined |
--------------------------------------------------
| Top |
托管标准,您可以接收以下服务:
1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;
2 随时在标准托管页面中查看到该条标准的最新状态;
3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;
4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;
5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;
6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;
标准资讯点击排行榜 全部
资讯标题点击
[[ n.title ]] [[ n.read ]]大连标准化公共服务平台
版权:大连标准化研究院有限公司
地址:大连市中山区高原街56号
电话:0411-82740851