委员会委托条例(EU) No 812/2013 ,补充关于热水器,热水储存罐和热水器及太阳能设备包的能源标签的欧洲议会和理事会指令2010/30/EU(1)

技术法规类型:欧盟Eurlex法规 来源:tbtmap

EURLEX ID:32013R0812

OJ编号:OJ L 239, 6.9.2013, p. 83-135

中文标题:委员会委托条例(EU) No 812/2013 ,补充关于热水器,热水储存罐和热水器及太阳能设备包的能源标签的欧洲议会和理事会指令2010/30/EU(1)

原文标题:Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device (1)

分类:15.20.20_消费者信息、教育与表现;12.10.20_合理利用与节约能源

文件类型:二级立法 Regulation|条例

生效日期:2013-09-26

废止日期:2058-12-31

法规全文:查看欧盟官方文件

HTML PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN"EN
6.9.2013 Official
Journal
of
the
European
Union L
239/83
COMMISSION DELEGATED REGULATION (EU) No 812/2013
of 18 February 2013
supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to
the energy labelling of water heaters, hot water storage tanks and packages of water heater and
solar device
(Text with EEA relevance)
THE EUROPEAN COMMISSION,
Regulation should introduce a new single labelling scale
from A to G for conventional water heaters, solar water
heaters and heat pump water heaters and for hot water
Having regard to the Treaty on the Functioning of the European
storage tanks. A dynamic class A + should be added to the
Union,
classification after two years to accelerate the market
penetration of the most efficient water heaters and hot
Having regard to Directive 2010/30/EU of the European
water storage tanks.
Parliament and of the Council of 19 May 2010 on the indi
cation by labelling and standard product information of the
consumption of energy and other resources by energy-related
(6) This
Regulation
should
ensure
that
consumers
get
more
products ( 1 ), and in particular Article 10 thereof,
accurate comparative information about the performance
of solar water heaters and heat pump water heaters in
three European climate zones.
Whereas:
(1) Directive
2010/30/EU
requires
the
Commission
to
adopt (7) The
sound
power
level
of
a
water
heater
could
be
an
delegated acts as regards the labelling of energy-related
important consideration for end-users. Information on
products that have a significant potential for energy
sound power levels should be included on the labels of
savings but exhibit a wide disparity in performance
water heaters.
levels with equivalent functionality.
(2) The
energy
consumed
by
water
heaters
and
hot
water (8) The
combined
effect
of
this
Regulation
and
Commission
storage tanks accounts for a significant share of the total
Regulation (EU) No 814/2013 of 2 August 2013 imple
energy demand in the Union, and water heaters and hot
menting Directive 2009/125/EC of the European
water storage tanks with equivalent functionality exhibit
Parliament and of the Council with regard to ecodesign
a wide disparity in terms of water heating energy effi
requirements for water heaters and hot water storage
ciency and standing loss. The scope for reducing their
tanks ( 2 ) is expected to result in estimated annual
energy consumption is significant and includes
energy savings of around 450 PJ (11 Mtoe) by 2020,
combining water heaters with appropriate solar devices.
corresponding to about 26 Mt CO 2 emissions,
Water heaters, hot water storage tanks and packages of
compared to what would happen if no measures were
water heaters and solar devices should therefore be
taken.
covered by energy labelling requirements.
(9) The
information
provided
on
the
labels
should
be
(3) Water
heaters
that
are
designed
for
using
gaseous
or
obtained through reliable, accurate and reproducible
liquid fuels predominantly (more than 50 %) produced
measurement and calculation procedures that take into
from biomass have specific technical characteristics
account recognised state-of-the-art measurement and
which require further technical, economic and environ
calculation methods including, where available,
mental analyses. Depending on the outcome of the
harmonised standards adopted by the European standard
analyses, energy labelling requirements for those water
isation bodies under a request from the Commission, in
heaters should be set at a later stage, if appropriate.
accordance with the procedures laid down in the
Directive 98/34/EC of the European Parliament and of
the Council of 22 June 1998 laying down a procedure
(4) Harmonised
provisions
should
be
laid
down
on
labelling
and standard product information regarding the energy
for the provision of information in the field of technical
efficiency of water heaters and hot water storage tanks in
standards and regulations and of rules on Information
order to provide incentives for manufacturers to improve
Society services ( 3 ), for the purpose of establishing
the energy efficiency of these products, to encourage end-
ecodesign requirements.
users to purchase energy-efficient products and to
contribute to the functioning of the internal market.
(10) This
Regulation
should
specify
a
uniform
design
and
content of product labels for water heaters and hot
(5) As
regards
significant
energy
and
cost
savings
for
each
water storage tanks.
type of water heater and for hot water storage tanks, this
( 2 ) See page 162 of this Official Journal.
( 1 ) OJ L 153, 18.6.2010, p. 1.
( 3 ) OJ L 204, 21.7.1998, p. 37.

L 239/84
EN
Official Journal of the European Union
6.9.2013
(11) In
addition,
this
Regulation
should
specify
requirements
Article 2
for the product fiche and technical documentation for
water heaters and hot water storage tanks.
Definitions
In addition to the definitions set out in Article 2 of Directive
2010/30/EU, the following definitions shall apply for the
(12) Moreover,
this
Regulation
should
specify
requirements
purposes of this Regulation:
for the information to be provided for any form of
distance selling of water heaters and hot water storage
tanks and in any advertisements and technical
(1) ‘water heater’ means a device that:
promotional material for such products.
(a) is connected to an external supply of drinking or
(13) In addition to the product labels and fiches for water
sanitary water;
heaters and hot water storage tanks laid down in this
Regulation, a package label and fiche based on product
fiches from suppliers should ensure that the end-user has
(b) generates and transfers heat to deliver drinking or
easy access to information on the energy performance of
sanitary hot water at given temperature levels, quan
water heaters in combination with solar devices. The
tities and flow rates during given intervals; and
most efficient class A +++ may be reached by such a
package.
(c) is equipped with one or more heat generators;
(14) It
is
appropriate
to
provide
for
a
review
of
the
provisions
of this Regulation taking into account technological
(2) ‘heat generator’ means the part of a water heater that
progress,
generates the heat using one or more of the following
processes:
HAS ADOPTED THIS REGULATION:
(a) combustion of fossil fuels and/or biomass fuels;
Article 1
Subject matter and scope
(b) use of the Joule effect in electric resistance heating
elements;
1. This Regulation establishes requirements for the energy
labelling of, and the provision of supplementary product
information on, water heaters with a rated heat output
(c) capture of ambient heat from an air source, water
≤ 70 kW, hot water storage tanks with a storage volume
source or ground source, and/or waste heat;
≤ 500 litres and packages of water heater ≤ 70 kW and solar
device.
(3) ‘rated heat output’ means the declared heat output of the
water heater when providing water heating at standard
2. This
Regulation
shall
not
apply
to:
rating conditions, expressed in kW;
(a) water heaters specifically designed for using gaseous or
(4) ‘storage volume’ (V) means the rated volume of a hot
liquid fuels predominantly produced from biomass;
water storage tank, expressed in litres;
(b) water heaters using solid fuels;
(5) ‘standard rating conditions’ means the operating
conditions of water heaters for establishing the rated
(c) water heaters within the scope of Directive 2010/75/EU of
heat output, water heating energy efficiency and sound
the European Parliament and of the Council (
power level, and of hot water storage tanks for estab

1 );
lishing the standing loss;
(d) combination heaters as defined in Article 2 of Commission
Delegated Regulation (EU) No 811/2013 ( 2 );
(6) ‘biomass’ means the biodegradable fraction of products,
waste and residues from biological origin from agriculture
(including vegetal and animal substances), forestry and
(e) water heaters which do not meet at least the load profile
related industries including fisheries and aquaculture, as
with the smallest reference energy, as specified in Annex VII,
well as the biodegradable fraction of industrial and
Table 3;
municipal waste;
(f) water heaters designed for making hot drinks and/or food
(7) ‘biomass fuel’ means a gaseous or liquid fuel produced
only.
from biomass;
( 1 ) OJ L 334, 17.12.2010, p. 17.
( 2 ) See page 1 of this Official Journal.
(8) ‘fossil fuel’ means a gaseous or liquid fuel of fossil origin;

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/85
(9) ‘hot water storage tank’ means a vessel for storing hot
(a) a printed label complying with the format and content of
water for water and/or space heating purposes, including
information set out in point 1.1 of Annex III is provided for
any additives, which is not equipped with any heat
each water heater conforming to the water heating energy
generator except possibly one or more back-up
efficiency classes set out in point 1 of Annex II, whereby:
immersion heaters;
for heat pump water heaters, the printed label is provided at
least in the packaging of the heat generator; for water
heaters intended for use in packages of water heater and
(10) ‘back-up immersion heater’ means a Joule effect electric
solar device, a second label complying with the format and
resistance heater that is part of a hot water storage tank
content of information set out in point 3 of Annex III is
and generates heat only when the external heat source is
provided for each water heater;
disrupted (including during maintenance periods) or out of
order, or that is part of a solar hot water storage tank and
provides heat when the solar heat source is not sufficient
(b) a product fiche, as set out in point 1 of Annex IV, is
to satisfy required comfort levels;
provided for each water heater, whereby: for heat pump
water heaters, the product fiche is provided at least for
the heat generator; for water heaters intended for use in
(11) ‘solar device’ means a solar-only system, a solar collector, a
packages of water heater and solar device, a second fiche,
solar hot water storage tank or a pump in the collector
as set out in point 4 of Annex IV, is provided;
loop, which are placed on the market separately;
(c) the technical documentation, as set out in point 1 of
(12) ‘solar-only system’ means a device that is equipped with
Annex V, is provided on request to the authorities of the
one or more solar collectors and solar hot water storage
Member States and to the Commission;
tanks and possibly pumps in the collector loop and other
parts, which is placed on the market as one unit and is not
equipped with any heat generator except possibly one or
(d) any advertisement relating to a specific water heater model
more back-up immersion heaters;
and containing energy-related or price information includes
a reference to the water heating energy efficiency class
under average climate conditions for that model;
(13) ‘package of water heater and solar device’ means a package
offered to the end-user containing one or more water
heaters and one or more solar devices;
(e) any technical promotional material concerning a specific
water heater model and describing its specific technical
parameters includes a reference to the water heating
(14) ‘water heating energy efficiency’ (η wh ) means the ratio
energy efficiency class under average climate conditions
between the useful energy provided by a water heater or
for that model.
a package of water heater and solar device and the energy
required for its generation, expressed in %;
From 26 September 2017 a printed label complying with the
format and content of information set out in point 1.2 of
(15) ‘sound power level’ (L WA ) means the A-weighted sound
Annex III shall be provided for each water heater conforming
power level, indoors and/or outdoors, expressed in dB;
to the water heating energy efficiency classes set out in point 1
of Annex II, whereby: for heat pump water heaters, the printed
label shall be provided at least in the packaging of the heat
(16) ‘standing loss’ (S) means the heating power dissipated from
generator.
a hot water storage tank at given water and ambient
temperatures, expressed in W;
2. From
26
September
2015
suppliers
placing
hot
water
storage tanks on the market and/or putting them into service
(17) ‘heat pump water heater’ means a water heater that uses
shall ensure that:
ambient heat from an air source, water source or ground
source, and/or waste heat for heat generation.
(a) a printed label complying with the format and content of
information set out in point 2.1 of Annex III is provided for
For the purposes of Annexes II to IX, additional definitions are
each hot water storage tank conforming to the energy effi
set out in Annex I.
ciency classes set out in point 2 of Annex II;
Article 3
(b) a product fiche, as set out in point 2 of Annex IV, is
provided;
Responsibilities of suppliers and timetable
1. From
26
September
2015
suppliers
placing
water
heaters
on the market and/or putting them into service, including those
(c) the technical documentation, as set out in point 2 of
integrated in packages of water heater and solar device, shall
Annex V, is provided on request to the authorities of the
ensure that:
Member States and to the Commission;

L 239/86
EN
Official Journal of the European Union
6.9.2013
(d) any advertisement relating to a specific hot water storage
reference to the water heating energy efficiency class
tank model and containing energy-related or price
under average climate conditions for that model.
information includes a reference to the energy efficiency
class for that model;
Article 4
(e) any technical promotional material concerning a specific
Responsibilities of dealers
hot water storage tank model and describing its specific
technical parameters includes a reference to the energy effi
1. Dealers
of
water
heaters
shall
ensure
that:
ciency class for that model.
(a) each water heater, at the point of sale, bears the label
From 26 September 2017 a printed label complying with the
provided by suppliers in accordance with Article 3(1), as
format and content of information as set out in point 2.2 of
set out in point 1 of Annex III, on the outside of the
Annex III shall be provided for each hot water storage tank
front of the appliance, in such a way as to be clearly visible;
conforming to the energy efficiency classes set out in point 2
of Annex II.
(b) water heaters offered for sale, hire or hire-purchase, where
the end-user cannot be expected to see the water heater
3. From
26
September
2015
suppliers
placing
solar
devices
displayed, are marketed with the information provided by
on the market and/or putting them into service shall ensure
the suppliers in accordance with point 1 of Annex VI;
that:
(c) any advertisement relating to a specific water heater model
(a) a product fiche, as set out in point 3 of Annex IV, is
and containing energy-related or price information includes
provided;
a reference to the water heating energy efficiency class
under average climate conditions for that model;
(b) the technical documentation, as set out in point 3 of
Annex V, is provided on request to the authorities of the
Member States and to the Commission.
(d) any technical promotional material concerning a specific
water heater model and describing its specific technical
parameters includes a reference to the water heating
4. From
26
September
2015
suppliers
placing
packages
of
energy efficiency class under average climate conditions
water heater and solar device on the market and/or putting
for that model.
them into service shall ensure that:
2. Dealers
of
hot
water
storage
tanks
shall
ensure
that:
(a) a printed label complying with the format and content of
information set out in point 3 of Annex III is provided for
each package of water heater and solar device conforming
(a) each hot water storage tank, at the point of sale, bears the
to the water heating energy efficiency classes set out in
label provided by suppliers in accordance with Article 3(2),
point 1 of Annex II;
as set out in point 2 of Annex III, on the outside of the
front of the appliance, in such a way as to be clearly visible;
(b) a product fiche, as set out in point 4 of Annex IV, is
provided for each package of water heater and solar device;
(b) hot water storage tanks offered for sale, hire or hire-
purchase, where the end-user cannot be expected to see
the hot water storage tank displayed, are marketed with
(c) the technical documentation, as set out in point 4 of
the information provided by the suppliers in accordance
Annex V, is provided on request to the authorities of the
with point 2 of Annex VI;
Member States and to the Commission;
(d) any advertisement relating to a specific package of water
(c) any advertisement relating to a specific hot water storage
heater and solar device model and containing energy-
tank model and containing energy-related or price
related or price information includes a reference to the
information includes a reference to the energy efficiency
water heating energy efficiency class under average climate
class for that model;
conditions for that model;
(d) any technical promotional material concerning a specific
(e) any technical promotional material concerning a specific
hot water storage tank model and describing its specific
package of water heater and solar device model and
technical parameters includes a reference to the energy effi
describing its specific technical parameters includes a
ciency class for that model.

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/87
3. Dealers of packages of water heater and solar device shall
Article 5
ensure, based on the label and fiches provided by suppliers in
accordance with Article 3(1), (3) and (4), that:
Measurement and calculation methods
The information to be provided pursuant to Articles 3 and 4
shall be obtained by reliable, accurate and reproducible
measurement and calculation methods which take into
(a) any offer for a specific package includes the water heating
account the recognised state-of-the-art measurement and calcu
energy efficiency and the water heating energy efficiency
lation methods, as set out in Annex VII and Annex VIII.
class for that package under average, colder or warmer
climate conditions, as applicable, by displaying with the
package the label set out in point 3 of Annex III and
Article 6
providing the fiche set out in point 4 of Annex IV, duly
Verification procedure for market surveillance purposes
filled in according to the characteristics of that package;
Member States shall apply the procedure set out in Annex IX
when assessing the conformity of the declared water heating
energy efficiency class, water heating energy efficiency, annual
(b) packages of water heater and solar device offered for sale,
energy consumption and sound power level of water heaters
hire or hire-purchase, where the end-user cannot be
and the declared energy efficiency class and standing loss of hot
expected to see the package of water heater and solar
water storage tanks.
device displayed, are marketed with the information
provided in accordance with point 3 of Annex VI;
Article 7
Review
The Commission shall review this Regulation in the light of
(c) any advertisement relating to a specific package of water
technological progress no later than five years after its entry
heater and solar device model and containing energy-
into force. The review shall in particular assess any significant
related or price information includes a reference to the
changes in the market shares of various types of appliances and
water heating energy efficiency class under average climate
the appropriateness of the package fiche and label set out in
conditions for that model;
point 3 of Annex III and point 4 of Annex IV.
Article 8
(d) any technical promotional material concerning a specific
Entry into force and application
package of water heater and solar device model and
describing its specific technical parameters includes a
This Regulation shall enter into force on the twentieth day
reference to the water heating energy efficiency class
following that of its publication in the Official Journal of the
under average climate conditions for that model.
European Union.
This Regulation shall be binding in its entirety and directly applicable in all Member States.
Done at Brussels, 18 February 2013.
For the Commission
The President
José Manuel BARROSO

L 239/88
EN
Official Journal of the European Union
6.9.2013
ANNEX I
Definitions applicable for Annexes II to IX
For the purposes of Annexes II to IX, the following definitions shall apply:
(1) ‘conventional water heater’ means a water heater that generates heat using the combustion of fossil and/or biomass
fuels and/or the Joule effect in electric resistance heating elements;
(2) ‘solar water heater’ means a water heater equipped with one or more solar collectors, solar hot water storage tanks,
heat generators and possibly pumps in the collector loop and other parts, a solar water heater is placed on the
market as one unit;
(3) ‘load profile’ means a given sequence of water draw-offs, as specified in Annex VII, Table 3; each water heater meets
at least one load profile;
(4) ‘water draw-off’ means a given combination of useful water flow rate, useful water temperature, useful energy
content and peak temperature, as specified in Annex VII, Table 3;
(5) ‘useful water flow rate’ (f) means the minimum flow rate, expressed in litres per minute, for which hot water is
contributing to the reference energy, as specified in Annex VII, Table 3;
(6) ‘useful water temperature’ (T m ) means the water temperature, expressed in degrees Celsius, at which hot water starts
contributing to the reference energy, as specified in Annex VII, Table 3;
(7) ‘useful energy content’ (Q tap ) means the energy content of hot water, expressed in kWh, provided at a temperature
equal to, or above, the useful water temperature, and at water flow rates equal to, or above, the useful water flow
rate, as specified in Annex VII, Table 3;
(8) ‘energy content of hot water’ means the product of the specific heat capacity of water, the average temperature
difference between the hot water output and cold water input, and the total mass of the hot water delivered;
(9) ‘peak temperature’ (T p ) means the minimum water temperature, expressed in degrees Celsius, to be achieved during
water draw-off, as specified in Annex VII, Table 3;
(10) ‘reference energy’ (Q ref ) means the sum of the useful energy content of water draw-offs, expressed in kWh, in a
particular load profile, as specified in Annex VII, Table 3;
(11) ‘maximum load profile’ means the load profile with the greatest reference energy that a water heater is able to
provide while fulfilling the temperature and flow rate conditions of that load profile;
(12) ‘declared load profile’ means the load profile applied when determining water heating energy efficiency;
(13) ‘conversion coefficient’ (CC) means a coefficient reflecting the estimated 40 % average EU generation efficiency
referred to in Directive 2012/27/EU of the European Parliament and of the Council ( 1 ); the value of the conversion
coefficient is CC = 2,5;
(14) ‘daily electricity consumption’ (Q elec ) means the consumption of electricity over 24 consecutive hours under the
declared load profile and under given climate conditions, expressed in kWh in terms of final energy;
(15) ‘daily fuel consumption’ (Q fuel ) means the consumption of fuels over 24 consecutive hours under the declared load
profile and under given climate conditions, expressed in kWh in terms of GCV, and for the purposes of point 4 in
Annex VIII expressed in GJ in terms of GCV;
(16) ‘gross calorific value’ (GCV) means the total amount of heat released by a unit quantity of fuel when it is burned
completely with oxygen and when the products of combustion are returned to ambient temperature; this quantity
includes the condensation heat of any water vapour contained in the fuel and of the water vapour formed by the
combustion of any hydrogen contained in the fuel;
(17) ‘smart control’ means a device that automatically adapts the water heating process to individual usage conditions
with the aim of reducing energy consumption;
( 1 ) OJ L 315, 14.11.2012, p. 1.

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/89
(18) ‘smart control compliance’ (smart) means the measure of whether a water heater equipped with smart controls fulfils
the criterion set out in point 5 of Annex VIII;
(19) ‘smart control factor’ (SCF) means the water heating energy efficiency gain due to smart control under the conditions
set out in point 3 of Annex VII;
(20) ‘weekly electricity consumption with smart controls’ (Q elec,week,smart ) means the weekly electricity consumption of a
water heater with the smart control function enabled, expressed in kWh in terms of final energy;
(21) ‘weekly fuel consumption with smart controls’ (Q fuel,week,smart ) means the weekly fuel consumption of a water heater
with the smart control function enabled, expressed in kWh in terms of GCV;
(22) ‘weekly electricity consumption without smart controls’ (Q elec,week ) means the weekly electricity consumption of a
water heater with the smart control function disabled, expressed in kWh in terms of final energy;
(23) ‘weekly fuel consumption without smart controls’ (Q fuel,week ) means the weekly fuel consumption of a water heater
with the smart control function disabled, expressed in kWh in terms of GCV;
(24) ‘annual electricity consumption’ (AEC) means the annual electricity consumption of a water heater under the
declared load profile and under given climate conditions, expressed in kWh in terms of final energy;
(25) ‘annual fuel consumption’ (AFC) means the annual fossil and/or biomass fuel consumption of a water heater under
the declared load profile and under given climate conditions, expressed in GJ in terms of GCV;
(26) ‘ambient correction term’ (Q cor ) means a term which takes into account the fact that the place where the water
heater is installed is not an isothermal place, expressed in kWh;
(27) ‘standby heat loss’ (P stby ) means the heat loss of a heat pump water heater in operating modes without heat demand,
expressed in kW;
(28) ‘average climate conditions’, ‘colder climate conditions’ and ‘warmer climate conditions’ mean the temperatures and
global solar irradiance conditions characteristic for the cities of Strasbourg, Helsinki and Athens, respectively;
(29) ‘annual energy consumption’ (Q tota ) means the annual energy consumption of a solar water heater, expressed in kWh
in terms of primary energy and/or kWh in terms of GCV;
(30) ‘annual non-solar heat contribution’ (Q nonsol ), means the annual contribution of electricity (expressed in kWh in
terms of primary energy) and/or fuels (expressed in kWh in terms of GCV) to the useful heat output of a solar water
heater or a package of water heater and solar device, taking into account the annual amount of heat captured by the
solar collector and the heat losses of the solar hot water storage tank;
(31) ‘solar collector’ means a device designed to absorb global solar irradiance and to transfer the heat energy so
produced to a fluid passing through it; it is characterised by the collector aperture area, the zero-loss efficiency,
the first order coefficient, the second-order coefficient and the incidence angle modifier;
(32) ‘global solar irradiance’ means the rate of total incoming solar energy, both direct and diffuse, on a collector plane
with an inclination of 45 degrees and southward orientation at the Earth’s surface, expressed in W/m 2 ;
(33) ‘collector aperture area’ (A sol ) means the maximum projected area through which unconcentrated solar radiation
enters the collector, expressed in m 2 ;
(34) ‘zero-loss efficiency’ (η 0 ) means the efficiency of the solar collector, when the solar collector mean fluid temperature
is equal to the ambient temperature;
(35) ‘first-order coefficient’ (a 1 ) means the heat loss coefficient of a solar collector, expressed in W/(m 2 K);
(36) ‘second-order coefficient’ (a 2 ) means the coefficient measuring the temperature dependence of the first order coef
ficient, expressed in W/(m 2 K 2 );
(37) ‘incidence angle modifier’ (IAM) means the ratio of the useful heat output of the solar collector at a given incidence
angle and its useful heat output at an incidence angle of 0 degrees;

L 239/90
EN
Official Journal of the European Union
6.9.2013
(38) ‘incidence angle’ means the angle between the direction to the sun and the direction perpendicular to the solar
collector aperture;
(39) ‘solar hot water storage tank’ means a hot water storage tank storing heat energy produced by one or more solar
collectors;
(40) ‘heat generator water heating energy efficiency’ (η wh,nonsol ) means the water heating energy efficiency of a heat
generator which is part of a solar water heater, expressed in %, established under average climate conditions and
without using solar heat input;
(41) ‘auxiliary electricity consumption’ (Q aux ), for the purpose of Figure 1 in Annex IV referred to as ‘auxiliary electricity’,
means the annual electricity consumption of a solar water heater or a solar-only system that is due to the pump
power consumption and the standby power consumption, expressed in kWh in terms of final energy;
(42) ‘pump power consumption’ (solpump) means the rated electrical power consumption of the pump in the collector
loop of a solar water heater or solar-only system, expressed in W;
(43) ‘standby power consumption’ (solstandby) means the rated electrical power consumption of a solar water heater or
solar-only system when the pump and the heat generator are inactive, expressed in W;
(44) ‘model identifier’ means the code, usually alphanumeric, which distinguishes a specific water heater, hot water
storage tank, solar device or package of water heater and solar device model from other models with the same
trade mark, supplier’s name or dealer’s name.

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/91
ANNEX II
Energy efficiency classes
1. WATER HEATING ENERGY EFFICIENCY CLASSES OF WATER HEATERS
The water heating energy efficiency class of a water heater shall be determined on the basis of its water heating energy
efficiency as set out in Table 1.
The water heating energy efficiency of a water heater shall be calculated in accordance with point 3 of Annex VIII, for
solar water heaters and heat pump water heaters under average climate conditions.
Table 1
Water heating energy efficiency classes of water heaters, categorised by declared load profiles, η wh in %
3XS XXS XS
S
M
L XL XXL
A +++
η wh ≥ 62
η wh ≥ 62
η wh ≥ 69
η wh ≥ 90 η wh ≥ 163 η wh ≥ 188 η wh ≥ 200 η wh ≥ 213
A ++
53 ≤ η wh
53 ≤ η wh
61 ≤ η wh
72 ≤ η wh 130 ≤ η wh 150 ≤ η wh 160 ≤ η wh 170 ≤ η wh
< 62
< 62
< 69
< 90
< 163
< 188
< 200
< 213
A +
44 ≤ η wh
44 ≤ η wh
53 ≤ η wh
55 ≤ η wh
100 ≤ η wh 115 ≤ η wh 123 ≤ η wh 131 ≤ η wh
< 53
< 53
< 61
< 72
< 130
< 150
< 160
< 170
A 35
≤ η wh
35 ≤ η wh
38 ≤ η wh
38 ≤ η wh
65 ≤ η wh
75 ≤ η wh
80 ≤ η wh
85 ≤ η wh
< 44
< 44
< 53
< 55
< 100
< 115
< 123
< 131
B 32
≤ η wh
32 ≤ η wh
35 ≤ η wh
35 ≤ η wh
39 ≤ η wh
50 ≤ η wh
55 ≤ η wh
60 ≤ η wh
< 35
< 35
< 38
< 38
< 65
< 75
< 80
< 85
C 29
≤ η wh
29 ≤ η wh
32 ≤ η wh
32 ≤ η wh
36 ≤ η wh
37 ≤ η wh
38 ≤ η wh
40 ≤ η wh
< 32
< 32
< 35
< 35
< 39
< 50
< 55
< 60
D 26
≤ η wh
26 ≤ η wh
29 ≤ η wh
29 ≤ η wh
33 ≤ η wh
34 ≤ η wh
35 ≤ η wh
36 ≤ η wh
< 29
< 29
< 32
< 32
< 36
< 37
< 38
< 40
E 22
≤ η wh
23 ≤ η wh
26 ≤ η wh
26 ≤ η wh
30 ≤ η wh
30 ≤ η wh
30 ≤ η wh
32 ≤ η wh
< 26
< 26
< 29
< 29
< 33
< 34
< 35
< 36
F 19
≤ η wh
20 ≤ η wh
23 ≤ η wh
23 ≤ η wh
27 ≤ η wh
27 ≤ η wh
27 ≤ η wh
28 ≤ η wh
< 22
< 23
< 26
< 26
< 30
< 30
< 30
< 32
G
η wh < 19
η wh < 20
η wh < 23
η wh < 23
η wh < 27
η wh < 27
η wh < 27
η wh < 28
2. ENERGY EFFICIENCY CLASSES OF HOT WATER STORAGE TANKS
The energy efficiency class of a hot water storage tank shall be determined on the basis of its standing loss as set out
in Table 2.
Table 2
Energy efficiency classes of hot water storage tanks
Energy efficiency class Standing
loss S in Watts, with storage volume V in litres
A+
S < 5,5 3,16 V 0,4
A 5,5 3,16 V 0,4 S < 8,5 4,25 V 0,4
B 8,5 4,25 V 0,4 S < 12 5,93 V 0,4
C 12 5,93 V 0,4 S < 16,66 8,33 V 0,4
D 16,66 8,33 V 0,4 S < 21 10,33 V 0,4
E 21 10,33 V 0,4 S < 26 13,66 V 0,4
F 26 13,66 V 0,4 S < 31 16,66 V 0,4
G
S > 31 16,66 V 0,4


L 239/92
EN
Official Journal of the European Union
6.9.2013
ANNEX III
The labels
1. WATER
HEATERS
1.1. Label
1
1.1.1. Conventional water heaters in water heating energy efficiency classes A to G

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/93
(a) The following information shall be included in the label:
I. supplier’s name or trade mark;
II. supplier’s model identifier;
III. the water heating function, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII;
IV. the water heating energy efficiency class, determined in accordance with point 1 of Annex II; the head of
the arrow containing the water heating energy efficiency class of the water heater shall be placed at the
same height as the head of the relevant energy efficiency class;
V. the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in
GJ in terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex
VIII;
VI. the sound power level L WA , indoors, in dB, rounded to the nearest integer;
VII. for conventional water heaters able to work only during off-peak hours, the pictogram referred to in point
4(d)(10) of this Annex may be added.
(b) The design aspects of the label for conventional water heaters shall be in accordance with point 4 of this Annex.


L 239/94
EN
Official Journal of the European Union
6.9.2013
1.1.2. Solar water heaters in water heating energy efficiency classes A to G
(a) The following information shall be included in the label:
I. supplier’s name or trade mark;
II. supplier’s model identifier;
III. the water heating function, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII;

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/95
IV. the water heating energy efficiency class under average climate conditions, determined in accordance with
point 1 of Annex II; the head of the arrow containing the water heating energy efficiency class of the
water heater shall be placed at the same height as the head of the relevant energy efficiency class;
V. the annual electricity consumption in kWh in terms of final energy or the annual fuel consumption in GJ
in terms of GCV, under average, colder and warmer climate conditions, rounded to the nearest integer and
calculated in accordance with point 4 of Annex VIII;
VI. European solar map displaying three indicative global solar irradiance zones;
VII. the sound power level L WA , indoors, in dB, rounded to the nearest integer.
(b) The design aspects of the label for solar water heaters shall be in accordance with point 5 of this Annex.


L 239/96
EN
Official Journal of the European Union
6.9.2013
1.1.3. Heat pump water heaters in water heating energy efficiency classes A to G
(a) The following information shall be included in the label:
I. supplier’s name or trade mark;
II. supplier’s model identifier;
III. the water heating function, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII;

EN
6.9.2013 Official
Journal
of
the
European
Union L
239/97
IV. the water heating energy efficiency class under average climate conditions, determined in accordance with
point 1 of Annex II; the head of the arrow containing the water heating energy efficiency class of the
water heater shall be placed at the same height as the head of the relevant energy efficiency class;
V. the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption
in GJ in terms of GCV, under average, colder and warmer climate conditions, rounded to the nearest
integer and calculated in accordance with point 4 of Annex VIII;
VI. European temperature map displaying three indicative temperature zones;
VII. the sound power level L WA , indoors (if applicable) and outdoors, in dB, rounded to the nearest integer;
VIII. for heat pump water heaters able to work only during off-peak hours, the pictogram referred to in point
6(d)(11) of this Annex may be added.
(b) The design aspects of the label for heat pump water heaters shall be in accordance with point 6 of this Annex.
By way of exception, where a model has been granted an ‘EU Ecolabel’ under Regulation (EC) No 66/2010 of
the European Parliament and of the Council ( 1 ), a copy of the EU Ecolabel may be added.
( 1 ) OJ L 27, 30.1.2010, p. 1.


L 239/98
EN
Official Journal of the European Union
6.9.2013
1.2. Label
2
1.2.1. Conventional water heaters in water heating energy efficiency classes A + to F
(a) The information listed in point 1.1.1(a) of this Annex shall be included in the label.
(b) The design aspects of the label for conventional water heaters shall be in accordance with point 4 of this
Annex.


EN
6.9.2013 Official
Journal
of
the
European
Union L
239/99
1.2.2. Solar water heaters in water heating energy efficiency classes A + to F
(a) The information listed in point 1.1.2(a) of this Annex shall be included in the label.
(b) The design aspects of the label for solar water heaters shall be in accordance with point 5 of this Annex.


L 239/100
EN
Official Journal of the European Union
6.9.2013
1.2.3. Heat pump water heaters in water heating energy efficiency classes A + to F
(a) The information listed in point 1.1.3(a) of this Annex shall be included in the label.
(b) The design aspects of the label for heat pump water heaters shall be in accordance with point 6 of this Annex.


EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/101
2. HOT
WATER
STORAGE
TANKS
2.1. Label
1
for
hot
water
storage
tanks
in
energy
efficiency
classes
A
to
G
(a) The following information shall be included in the label:
I. supplier’s name or trade mark;
II. supplier’s model identifier;
III. the water storage function;
IV. the energy efficiency class, determined in accordance with point 2 of Annex II; the head of the arrow
containing the energy efficiency class of the hot water storage tank shall be placed at the same height as
the head of the relevant energy efficiency class;

L 239/102
EN
Official Journal of the European Union
6.9.2013
V. the standing loss in W, rounded to the nearest integer;
VI. the hot water storage tank volume in litres, rounded to the nearest integer.
(b) The design aspects of the label for hot water storage tanks shall be in accordance with point 7 of this Annex.


EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/103
2.2. Label
2
for
hot
water
storage
tanks
in
energy
efficiency
classes
A + to F
(a) The information listed in point 2.1(a) of this Annex shall be included in the label.
(b) The design aspects of the label for hot water storage tanks shall be in accordance with point 7 of this Annex.


L 239/104
EN
Official Journal of the European Union
6.9.2013
3. PACKAGES
OF
WATER
HEATER
AND
SOLAR
DEVICE
Label for packages of water heater and solar device in water heating energy efficiency classes A +++ to G
(a) The following information shall be included in the label:
I. dealer’s and/or supplier's name or trade mark;
II. dealer’s and/or supplier's model(s) identifier;
III. the water heating function, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII;

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/105
IV. the water heating energy efficiency class of the water heater, determined in accordance with point 1 of
Annex II;
V. indication of whether a solar collector and hot water storage tank may be included in the package of water
heater and solar device;
VI. the water heating energy efficiency class of the package of water heater and solar device, determined in
accordance with point 4 of Annex IV; the head of the arrow containing the water heating energy efficiency
class of the package of water heater and solar device shall be placed at the same height as the head of the
relevant energy efficiency class.
(b) The design aspects of the label for packages of water heater and solar device shall be in accordance with point
8 of this Annex. For packages of water heater and solar device in water heating energy efficiency classes A +++
to D, the last classes E to G in the A +++ to G scale may be omitted.


L 239/106
EN
Official Journal of the European Union
6.9.2013
4.
The design of the label for conventional water heaters shall be the following:
Whereby:
(a) The label shall be at least 105 mm wide and 200 mm high. Where the label is printed in a larger format, its
content shall nevertheless remain proportionate to the specifications above.
(b) The background shall be white.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/107
(c) Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 %
cyan, 70 % magenta, 100 % yellow, 0 % black.
(d) The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 4 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 86 mm, height:
17 mm.
Sub-logos border: 1 pt, colour: cyan 100 %, length: 86 mm.
Water heating function:
— Pictogram as depicted, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII: Calibri bold 16 pt, 100 % black.
A-G or A + -F scale:
— Arrow: height: 7 mm, gap: 1 mm, colours:
Highest class: X-00-X-00,
Second class: 70-00-X-00,
Third class: 30-00-X-00,
Fourth class: 00-00-X-00,
Fifth class: 00-30-X-00,
Sixth class: 00-70-X-00,
Last class: 00-X-X-00,
— Text: Calibri bold 16 pt, capitals, white, ‘+’ symbol: superscript.
Water heating energy efficiency class:
— Arrow: width: 22 mm, height: 12 mm, 100 % black,
— Text: Calibri bold 24 pt, capitals, white, ‘+’ symbol: superscript.
Sound power level, indoors:
— Pictogram as depicted,
— Border: 2 pt – colour: cyan 100 % – round corners: 3,5 mm,
— Value ‘YZ’: Calibri bold 15 pt, 100 % black,
— Text ‘dB’: Calibri regular 10 pt, 100 % black.
Annual energy consumption in kWh/annum or GJ/annum:
— Border: 2 pt – colour: cyan 100 % – round corners: 3,5 mm,
— Value ‘WXYZ’ or ‘YZ’: Calibri bold at least 20 pt, 100 % black,
— Text ‘kWh/annum’ or ‘GJ/annum’: Calibri regular at least 15 pt, 100 % black.
If applicable, off-peak fitness:
— Pictogram as depicted,
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm.
Year of label introduction and number of Regulation:
— Text: Calibri bold 10 pt.
Supplier’s name or trademark.
Supplier’s model identifier:
The supplier’s name or trade mark and model identifier shall fit in a space of 86 × 12 mm.


L 239/108
EN
Official Journal of the European Union
6.9.2013
5.
The design of the label for solar water heaters shall be the following:
Whereby:
(a) The label shall be at least 105 mm wide and 200 mm high. Where the label is printed in a larger format, its
content shall nevertheless remain proportionate to the specifications above.
(b) The background shall be white.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/109
(c) Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 %
cyan, 70 % magenta, 100 % yellow, 0 % black.
(d) The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 4 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 86 mm, height:
17 mm.
Sub-logos border: 1 pt, colour: cyan 100 %, length: 86 mm.
Water heating function:
— Pictogram as depicted, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII: Calibri bold 16 pt, 100 % black.
A-G or A + -F scale:
— Arrow: height: 7 mm, gap: 1 mm, colours:
Highest class: X-00-X-00,
Second class: 70-00-X-00,
Third class: 30-00-X-00,
Fourth class: 00-00-X-00,
Fifth class: 00-30-X-00,
Sixth class: 00-70-X-00,
Last class: 00-X-X-00,
— Text: Calibri bold 16 pt, capitals, white, ‘+’ symbol: superscript.
Water heating energy efficiency class:
— Arrow: width: 22 mm, height: 12 mm, 100 % black,
— Text: Calibri bold 24 pt, capitals, white, ‘+’ symbol: superscript.
Sound power level, indoors:
— Pictogram as depicted,
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,
— Value ‘YZ’: Calibri bold 15 pt, 100 % black,
— Text ‘dB’: Calibri regular 10 pt, 100 % black.
Annual energy consumption in kWh/annum or GJ/annum:
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,
— Values ‘WXYZ’ or ‘YZ’: Calibri at least 13 pt, 100 % black,
— Text ‘kWh/annum’ or ‘GJ/annum’: Calibri regular at least 11 pt, 100 % black.
European solar map and colour squares:
— Pictogram as depicted,
— Colours: Dark blue: 86-51-00-00,
Middle blue: 53-08-00-00,
Light blue: 25-00-02-00.
Year of label introduction and number of Regulation:
— Text: Calibri bold 10 pt.
Supplier’s name or trademark.
Supplier’s model identifier:
The supplier’s name or trade mark and model identifier shall fit in a space of 86 × 12 mm.


L 239/110
EN
Official Journal of the European Union
6.9.2013
6.
The design of the label for heat pump water heaters shall be the following:
Whereby:
(a) The label shall be at least 105 mm wide and 200 mm high. Where the label is printed in a larger format, its
content shall nevertheless remain proportionate to the specifications above.
(b) The background shall be white.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/111
(c) Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 %
cyan, 70 % magenta, 100 % yellow, 0 % black.
(d) The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 4 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 86 mm, height:
17 mm.
Sub-logos border: 1 pt, colour: cyan 100 %, length: 86 mm.
Water heating function:
— Pictogram as depicted, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII: Calibri bold 16 pt, 100 % black.
A-G or A + -F scale:
— Arrow: height: 7 mm, gap: 1 mm, colours:
Highest class: X-00-X-00,
Second class: 70-00-X-00,
Third class: 30-00-X-00,
Fourth class: 00-00-X-00,
Fifth class: 00-30-X-00,
Sixth class: 00-70-X-00,
Last class: 00-X-X-00,
— Text: Calibri bold 16 pt, capitals, white, ‘+’ symbol: superscript.
Water heating energy efficiency class:
— Arrow: width: 22 mm, height: 12 mm, 100 % black,
— Text: Calibri bold 24 pt, capitals, white, ‘+’ symbol: superscript.
Sound power level, indoors (if applicable) and outdoors:
— Pictogram as depicted,
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,
— Value ‘YZ’: Calibri bold 15 pt, 100 % black,
— Text ‘dB’: Calibri regular 10 pt, 100 % black.
Annual energy consumption in kWh/annum or GJ/annum:
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,
— Values ‘WXYZ’ or ‘YZ’: Calibri at least 13 pt, 100 % black,
— Text ‘kWh/annum’ or ‘GJ/annum’: Calibri regular at least 11 pt, 100 % black.
European temperature map and colour squares:
— Pictogram as depicted,
— Colours: Dark blue: 86-51-00-00,
Middle blue: 53-08-00-00,
Light blue: 25-00-02-00.
If applicable, off-peak fitness:
— Pictogram as depicted,
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm.
Year of label introduction and number of Regulation:
— Text: Calibri bold 10 pt.
Supplier’s name or trademark.
Supplier’s model identifier:
The supplier’s name or trade mark and model identifier shall fit in a space of 86 × 12 mm.


L 239/112
EN
Official Journal of the European Union
6.9.2013
7.
The design of the label for hot water storage tanks shall be the following:
Whereby:
(a) The label shall be at least 105 mm wide and 200 mm high. Where the label is printed in a larger format, its
content shall nevertheless remain proportionate to the specifications above.
(b) The background shall be white.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/113
(c) Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 %
cyan, 70 % magenta, 100 % yellow, 0 % black.
(d) The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 4 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 86 mm, height:
17 mm.
Sub-logos border: 1 pt, colour: cyan 100 %, length: 86 mm.
Storage function:
— Pictogram as depicted.
A-G or A + -F scale:
— Arrow: height: 7 mm, gap: 1 mm, colours:
Highest class: X-00-X-00,
Second class: 70-00-X-00,
Third class: 30-00-X-00,
Fourth class: 00-00-X-00,
Fifth class: 00-30-X-00,
Sixth class: 00-70-X-00,
Last class: 00-X-X-00,
— Text: Calibri bold 16 pt, capitals, white, ‘+’ symbol: superscript.
Energy efficiency class:
— Arrow: width: 22 mm, height: 12 mm, 100 % black,
— Text: Calibri bold 24 pt, capitals, white, ‘+’ symbol: superscript.
Standing loss:
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,
— Value ‘YZ’: Calibri bold 45 pt, 100 % black,
— Text ‘W’: Calibri regular 30 pt, 100 % black.
Storage volume:
— Border: 2 pt, colour: cyan 100 %, round corners: 3,5 mm,
— Value ‘XYZ’: Calibri bold 45 pt, 100 % black,
— Text ‘L’: Calibri regular 30 pt, 100 % black.
Year of label introduction and number of Regulation:
— Text: Calibri bold 10 pt.
Supplier’s name or trademark.
Supplier’s model identifier:
The supplier’s name or trade mark and model identifier shall fit in a space of 86 × 12 mm.


L 239/114
EN
Official Journal of the European Union
6.9.2013
8.
The design of the label for packages of water heater and solar device shall be the following:
Whereby:
(a) The label shall be at least 210 mm wide and 297 mm high. Where the label is printed in a larger format, its
content shall nevertheless remain proportionate to the specifications above.
(b) The background shall be white.
(c) Colours are coded as CMYK — cyan, magenta, yellow and black, following this example: 00-70-X-00: 0 %
cyan, 70 % magenta, 100 % yellow, 0 % black.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/115
(d) The label shall fulfil all of the following requirements (numbers refer to the figure above):
EU label border stroke: 6 pt, colour: cyan 100 %, round corners: 3,5 mm.
EU logo: Colours: X-80-00-00 and 00-00-X-00.
Energy label: Colour: X-00-00-00. Pictogram as depicted: EU logo + energy label: width: 191 mm, height:
37 mm.
Sub-logos border: 2 pt, colour: cyan 100 %, length: 191 mm.
Water heating function:
— Pictogram as depicted, including the declared load profile expressed as the appropriate letter in
accordance with Table 3 of Annex VII: Calibri bold 22 pt, 100 % black.
Water Heater:
— Pictogram as depicted.
— Water heating energy efficiency class of water heater:
Arrow: width: 24 mm, height: 14 mm, 100 % black,
Text: Calibri bold 28 pt, capitals, white,
— Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
Package with solar collector and/or hot water storage tank:
— Pictograms as depicted,
— ‘+’ symbol: Calibri bold 50 pt, cyan 100 %,
— Boxes: width: 12 mm, height: 12 mm, border: 4 pt, cyan 100 %,
— Border: 3 pt – colour: cyan 100 % – round corners: 3,5 mm.
A +++ -G scale with border:
— Arrow: height: 15 mm, gap: 3 mm, colours:
Highest class: X-00-X-00,
Second class: 70-00-X-00,
Third class: 30-00-X-00,
Fourth class: 00-00-X-00,
Fifth class: 00-30-X-00,
Sixth class: 00-70-X-00,
Seventh class: 00-X-X-00,
If applicable, last classes: 00-X-X-00,
— Text: Calibri bold 30 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row,
— Border: 3 pt, colour: cyan 100 %, round corners: 3,5 mm.
Water heating energy efficiency class for package of water heater and solar device:
— Arrow: width: 33 mm, height: 19 mm, 100 % black,
— Text: Calibri bold 40 pt, capitals, white, ‘+’ symbols: superscript, aligned on a single row.
Year of label introduction and number of Regulation:
— Text: Calibri bold 12 pt.
Dealer’s and/or supplier's name or trademark.
Dealer’s and/or supplier's model identifier:
The dealer’s and/or supplier's name or trade mark and model identifier shall fit in a space of 191 × 19 mm.

L 239/116
EN
Official Journal of the European Union
6.9.2013
ANNEX IV
Product Fiche
1. WATER
HEATERS
1.1. The information in the product fiche of the water heater shall be provided in the following order and shall be
included in the product brochure or other literature provided with the product:
(a) supplier’s name or trade mark;
(b) supplier’s model identifier;
(c) the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of
Annex VII;
(d) the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II,
whereby: for solar water heaters and heat pump water heaters, under average climate conditions;
(e) the water heating energy efficiency in %, rounded to the nearest integer and calculated in accordance with point
3 of Annex VIII, whereby: for solar water heaters and heat pump water heaters, under average climate
conditions;
(f) the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in
terms of GCV, rounded to the nearest integer and calculated in accordance with point 4 of Annex VIII, whereby:
for solar water heaters and heat pump water heaters, under average climate conditions;
(g) if applicable, other load profiles for which the water heater is suitable to use and the corresponding water
heating energy efficiency and annual electricity consumption as set out in points (e) and (f);
(h) the thermostat temperature settings of the water heater, as placed on the market by the supplier;
(i) the sound power level L WA , indoors, in dB, rounded to the nearest integer (for heat pump water heaters if
applicable);
(j) if applicable, an indication that the water heater is able to work only during off-peak hours;
(k) any specific precautions that shall be taken when the water heater is assembled, installed or maintained;
(l) where the value of smart is declared as being ‘1’, an indication that the information on water heating energy
efficiency, annual electricity and fuel consumption, as applicable, relate to enabled smart control settings only;
in addition, for solar water heaters and heat pump water heaters:
(m) the water heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest
integer and calculated in accordance with point 3 of Annex VIII;
(n) the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ
in terms of GCV, under colder and warmer climate conditions, rounded to the nearest integer and calculated in
accordance with point 4 of Annex VIII;
in addition, for solar water heaters:
(o) the collector aperture area in m 2 , to two decimal places;
(p) the zero-loss efficiency, to three decimal places;
(q) the first-order coefficient in W/(m 2 K), to two decimal places;
(r) the second-order coefficient in W/(m 2 K 2 ), to three decimal places;
(s) the incidence angle modifier, to two decimal places;
(t) the storage volume in litres, rounded to the nearest integer;
(u) the pump power consumption in W, rounded to the nearest integer;
(v) the standby power consumption in W, to two decimal places;
in addition, for heat pump water heaters:
(w) the sound power level L WA , outdoors, in dB, rounded to the nearest integer.
1.2. One fiche may cover a number of water heater models supplied by the same supplier.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/117
1.3. The information contained in the fiche may be given in the form of a copy of the label, either in colour or in black
and white. Where this is the case, the information listed in point 1.1 not already displayed on the label shall also be
provided.
2. HOT
WATER
STORAGE
TANKS
2.1. The information in the product fiche of the hot water storage tank shall be provided in the following order and shall
be included in the product brochure or other literature provided with the product:
(a) supplier’s name or trade mark;
(b) supplier’s model identifier;
(c) the energy efficiency class of the model, determined in accordance with point 2 of Annex II;
(d) the standing loss in W, rounded to the nearest integer;
(e) the storage volume in litres, rounded to the nearest integer.
2.2. One fiche may cover a number of hot water storage tank models supplied by the same supplier.
2.3. The information contained in the fiche may be given in the form of a copy of the label, either in colour or in black
and white. Where this is the case, the information listed in point 2.1 not already displayed on the label shall also be
provided.
3. SOLAR
DEVICES
3.1. The information in the product fiche of the solar device shall be provided in the following order and shall be
included in the product brochure or other literature provided with the product (for pumps in the collector loop if
applicable):
(a) supplier’s name or trade mark;
(b) supplier’s model identifier;
(c) the collector aperture area in m 2 , to two decimal places;
(d) the zero-loss efficiency, to three decimal places;
(e) the first-order coefficient in W/(m 2 K), to two decimal places;
(f) the second-order coefficient in W/(m 2 K 2 ), to three decimal places;
(g) the incidence angle modifier, to two decimal places;
(h) the storage volume in litres, rounded to the nearest integer;
(i) the annual non-solar heat contribution Q nonsol in kWh in terms of primary energy for electricity and/or in kWh
in terms of GCV for fuels, for the load profiles M, L, XL and XXL under average climate conditions, rounded to
the nearest integer;
(j) the pump power consumption in W, rounded to the nearest integer;
(k) the standby power consumption in W, to two decimal places;
(l) the annual auxiliary electricity consumption Q aux in kWh in terms of final energy, rounded to the nearest
integer.
3.2. One fiche may cover a number of solar device models supplied by the same supplier.
4. PACKAGES
OF
WATER
HEATER
AND
SOLAR
DEVICE
The fiche for packages of water heater and solar device shall contain the elements set out in Figure 1 for evaluating
the water heating energy efficiency of a package of water heater and solar device, where the following information
shall be included:
— I: the value of the water heating energy efficiency of the water heater, expressed in %,
— II: the value of the mathematical expression 220 Q ref =Q nonsol , where Q ref is taken from Table 3 in Annex VII
and Q nonsol from the product fiche of the solar device for the declared load profile M, L, XL or XXL of the water
heater,
— III: the value of the mathematical expression Q aux 2,5=220 Q ref , expressed in %, where Q aux is taken from
the product fiche of the solar device and Q ref from Table 3 in Annex VII for the declared load profile M, L, XL or
XXL.


L 239/118
EN
Official Journal of the European Union
6.9.2013
Figure 1
Fiche for a package of water heater and solar device indicating the water heating energy efficiency of the
package offered

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/119
ANNEX V
Technical documentation
1. WATER HEATERS
For water heaters, the technical documentation referred to in Article 3(1)(c) shall include:
(a) the name and address of the supplier;
(b) a description of the water heater model sufficient for its unambiguous identification;
(c) where appropriate, the references of the harmonised standards applied;
(d) where appropriate, the other technical standards and specifications used;
(e) the identification and signature of the person empowered to bind the supplier;
(f) the results of the measurements for the technical parameters specified in point 7 of Annex VII;
(g) the results of the calculations for the technical parameters specified in point 2 of Annex VIII;
(h) any specific precautions that shall be taken when the water heater is assembled, installed or maintained.
2. HOT WATER STORAGE TANKS
For hot water storage tanks, the technical documentation referred to in Article 3(2)(c) shall include:
(a) the name and address of the supplier;
(b) a description of the hot water storage tank model sufficient for its unambiguous identification;
(c) where appropriate, the references of the harmonised standards applied;
(d) where appropriate, the other technical standards and specifications used;
(e) the identification and signature of the person empowered to bind the supplier;
(f) the results of the measurements for the technical parameters specified in point 8 of Annex VII;
(g) any specific precautions that shall be taken when the hot water storage tank is assembled, installed or maintained.
3. SOLAR DEVICES
The technical documentation of solar devices referred to in Article 3(3)(b) shall include:
(a) the name and address of the supplier;
(b) a description of the solar device model sufficient for its unambiguous identification;
(c) where appropriate, the references of the harmonised standards applied;
(d) where appropriate, the other technical standards and specifications used;
(e) the identification and signature of the person empowered to bind the supplier;
(f) the results of the measurements for the technical parameters as specified in point 9 of Annex VII;
(g) any specific precautions that shall be taken when the solar device is assembled, installed or maintained.

L 239/120
EN
Official Journal of the European Union
6.9.2013
4. PACKAGES OF WATER HEATER AND SOLAR DEVICE
For packages of water heater and solar device, the technical documentation referred to in Article 3(4)(c) shall include:
(a) the name and address of the supplier;
(b) a description of the package of water heater and solar device model sufficient for its unambiguous identification;
(c) where appropriate, the references of the harmonised standards applied;
(d) where appropriate, the other technical standards and specifications used;
(e) the identification and signature of the person empowered to bind the supplier;
(f) technical parameters:
— the water heating energy efficiency in %, rounded to the nearest integer,
— the technical parameters set out in points 1, 2 and 3 of this Annex;
(g) any specific precautions that shall be taken when the package of water heater and solar device is assembled,
installed or maintained.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/121
ANNEX VI
Information to be provided in cases where end-users cannot be expected to see the product displayed
1. WATER
HEATERS
1.1. The information referred to in Article 4(1)(b) shall be provided in the following order:
(a) the declared load profile, expressed by the appropriate letter and typical usage in accordance with Table 3 of
Annex VII;
(b) the water heating energy efficiency class of the model, under average climate conditions, in accordance with
point 1 of Annex II;
(c) the water heating energy efficiency in %, under average climate conditions, rounded to the nearest integer and
calculated in accordance with point 3 of Annex VIII;
(d) the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in
terms of GCV, under average climate conditions, rounded to the nearest integer and calculated in accordance
with point 4 of Annex VIII;
(e) the sound power level, indoors, in dB, rounded to the nearest integer (for heat pump water heaters, if applicable);
in addition, for solar water heaters and heat pump water heaters:
(f) the water heating energy efficiency in %, under colder and warmer climate conditions, rounded to the nearest
integer and calculated in accordance with point 3 of Annex VIII;
(g) the annual electricity consumption in kWh in terms of final energy and/or the annual fuel consumption in GJ in
terms of GCV, under colder and warmer climate conditions, rounded to the nearest integer and calculated in
accordance with point 4 of Annex VIII;
in addition, for solar water heaters:
(h) the collector aperture area in m 2 , to two decimal places;
(i) the storage volume in litres, rounded to the nearest integer;
in addition, for heat pump water heaters:
(j) the sound power level, outdoors, in dB, rounded to the nearest integer.
1.2. Where other information contained in the product fiche is also provided, it shall be in the form and order specified
in point 1 of Annex IV.
1.3. The size and font in which the information referred in points 1.1 and 1.2 is printed or shown shall be legible.
2. HOT
WATER
STORAGE
TANKS
2.1. The information referred to in Article 4(2)(b) shall be provided in the following order:
(a) the energy efficiency class of the model, determined in accordance with point 2 of Annex II;
(b) the standing loss in W, rounded to the nearest integer;
(c) the storage volume in litres, rounded to the nearest integer.
2.2. The size and font in which the information referred in point 2.1 is printed or shown shall be legible.

L 239/122
EN
Official Journal of the European Union
6.9.2013
3. PACKAGES
OF
WATER
HEATER
AND
SOLAR
DEVICE
3.1. The information referred to in Article 4(3)(b) shall be provided in the following order:
(a) the water heating energy efficiency class of the model, determined in accordance with point 1 of Annex II;
(b) the water heating energy efficiency in %, rounded to the nearest integer;
(c) the elements set out in Figure 1 of Annex IV.
3.2. The size and font in which the information referred in point 3.1 is printed or shown shall be legible.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/123
ANNEX VII
Measurements
1. For the purposes of compliance and verification of compliance with the requirements of this Regulation,
measurements shall be made using harmonised standards the reference numbers of which have been published for
this purpose in the Official Journal of the European Union, or using other reliable, accurate and reproducible
measurement methods that take into account the generally recognised state-of-the-art methods. They shall meet the
conditions and technical parameters set out in points 2 to 9.
2. General conditions for testing water heaters:
(a) measurements shall be carried out using the load profiles set out in Table 3;
(b) measurements shall be carried out using a 24-hour measurement cycle as follows:
— 00:00 to 06:59: no water draw-off,
— from 07:00: water draw-offs according to the declared load profile,
— from end of last water draw-off until 24:00: no water draw-off;
(c) the declared load profile shall be the maximum load profile or the load profile one below the maximum load
profile.
Table 3
Load profiles of water heaters
3XS XXS XS
S
h
Q tap
f
T m
Q tap
f
T m
Q tap
f
T m
Q tap
f
T m
T p
kWh l/min °C kWh l/min °C kWh l/min °C kWh l/min °C °C
07:00 0,015
2 25 0,105
2 25 0,105
3 25
07:05 0,015
2 25
07:15 0,015
2 25
07:26 0,015
2 25
07:30 0,015
2 25 0,105
2 25 0,525
3 35 0,105
3 25
07:45
08:01
08:05
08:15
08:25
08:30 0,105
2 25 0,105
3 25
08:45
09:00 0,015
2 25
09:30 0,015
2 25 0,105
2 25 0,105
3 25
10:00
10:30
11:00

L 239/124
EN
Official Journal of the European Union
6.9.2013
3XS XXS XS
S
h
Q tap
f
T m
Q tap
f
T m
Q tap
f
T m
Q tap
f
T m
T p
kWh l/min °C kWh l/min °C kWh l/min °C kWh l/min °C °C
11:30 0,015
2 25 0,105
2 25 0,105
3 25
11:45 0,015
2 25 0,105
2 25 0,105
3 25
12:00 0,015
2 25 0,105
2 25
12:30 0,015
2 25 0,105
2 25
12:45 0,015
2 25 0,105
2 25 0,525
3 35 0,315
4 10 55
14:30 0,015
2 25
15:00 0,015
2 25
15:30 0,015
2 25
16:00 0,015
2 25
16:30
17:00
18:00 0,105
2 25 0,105
3 25
18:15 0,105
2 25 0,105
3 40
18:30 0,015
2 25 0,105
2 25
19:00 0,015
2 25 0,105
2 25
19:30 0,015
2 25 0,105
2 25
20:00 0,105
2 25
20:30 1,05
3 35 0,42
4 10 55
20:45 0,105
2 25
20:46
21:00 0,105
2 25
21:15 0,015
2 25 0,105
2 25
21:30 0,015
2 25 0,525
5 45
21:35 0,015
2 25 0,105
2 25
21:45 0,015
2 25 0,105
2 25
Q ref
0,345 2,100 2,100 2,100
Continued Table 3
Load profiles of water heaters
M
L XL
h
Q tap
f
T m
T p
Q tap
f
T m
T p
Q tap
f
T m
T p
kWh l/min °C °C kWh l/min °C °C kWh l/min °C °C
07:00 0,105
3 25 0,105
3 25 0,105
3 25
07:05 1,4
6 40 1,4
6 40

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/125
M
L XL
h
Q tap
f
T m
T p
Q tap
f
T m
T p
Q tap
f
T m
T p
kWh l/min °C °C kWh l/min °C °C kWh l/min °C °C
07:15
1,82
6 40
07:26 0,105
3 25
07:30 0,105
3 25 0,105
3 25
07:45 0,105
3 25 4,42 10 10 40
08:01 0,105
3 25 0,105
3 25
08:05 3,605 10 10 40
08:15 0,105
3 25 0,105
3 25
08:25 0,105
3 25
08:30 0,105
3 25 0,105
3 25 0,105
3 25
08:45 0,105
3 25 0,105
3 25 0,105
3 25
09:00 0,105
3 25 0,105
3 25 0,105
3 25
09:30 0,105
3 25 0,105
3 25 0,105
3 25
10:00 0,105
3 25
10:30 0,105
3 10 40 0,105
3 10 40 0,105
3 10 40
11:00 0,105
3 25
11:30 0,105
3 25 0,105
3 25 0,105
3 25
11:45 0,105
3 25 0,105
3 25 0,105
3 25
12:00
12:30
12:45 0,315
4 10 55 0,315
4 10 55 0,735
4 10 55
14:30 0,105
3 25 0,105
3 25 0,105
3 25
15:00 0,105
3 25
15:30 0,105
3 25 0,105
3 25 0,105
3 25
16:00 0,105
3 25
16:30 0,105
3 25 0,105
3 25 0,105
3 25
17:00 0,105
3 25
18:00 0,105
3 25 0,105
3 25 0,105
3 25
18:15 0,105
3 40 0,105
3 40 0,105
3 40
18:30 0,105
3 40 0,105
3 40 0,105
3 40

L 239/126
EN
Official Journal of the European Union
6.9.2013
M
L XL
h
Q tap
f
T m
T p
Q tap
f
T m
T p
Q tap
f
T m
T p
kWh l/min °C °C kWh l/min °C °C kWh l/min °C °C
19:00 0,105
3 25 0,105
3 25 0,105
3 25
19:30
20:00
20:30 0,735
4 10 55 0,735
4 10 55 0,735
4 10 55
20:45
20:46
4,42 10 10 40
21:00 3,605 10 10 40
21:15 0,105
3 25 0,105
3 25
21:30 1,4
6 40 0,105
3 25 4,42 10 10 40
21:35
21:45
Q ref
5,845 11,655 19,07
Continued Table 3
Load profiles of water heaters
XXL
h
Q tap
f
T m
T p
kWh l/min °C °C
07:00 0,105
3 25
07:05
07:15 1,82
6 40
07:26 0,105
3 25
07:30
07:45 6,24 16 10 40
08:01 0,105
3 25
08:05
08:15 0,105
3 25
08:25
08:30 0,105
3 25
08:45 0,105
3 25
09:00 0,105
3 25
09:30 0,105
3 25
10:00 0,105
3 25

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/127
XXL
h
Q tap
f
T m
T p
kWh l/min °C °C
10:30 0,105
3 10 40
11:00 0,105
3 25
11:30 0,105
3 25
11:45 0,105
3 25
12:00
12:30
12:45 0,735
4 10 55
14:30 0,105
3 25
15:00 0,105
3 25
15:30 0,105
3 25
16:00 0,105
3 25
16:30 0,105
3 25
17:00 0,105
3 25
18:00 0,105
3 25
18:15 0,105
3 40
18:30 0,105
3 40
19:00 0,105
3 25
19:30
20:00
20:30 0,735
4 10 55
20:45
20:46 6,24 16 10 40
21:00
21:15 0,105
3 25
21:30 6,24 16 10 40
21:35
21:45
Q ref
24,53
3. Conditions for testing the smart control compliance (smart) of water heaters
Where the supplier deems it appropriate to declare the value of smart as being ‘1’, measurements of the weekly
electricity and/or fuel consumption with smart controls and the weekly electricity and/or fuel consumption without
smart controls shall be carried out using a two-week measurement cycle as follows:
— days 1 to 5: random sequence of load profiles chosen from the declared load profile and the load profile one
below the declared load profile, and smart control disabled,

L 239/128
EN
Official Journal of the European Union
6.9.2013
— days 6 and 7: no water draw-offs, and smart control disabled,
— days 8 to 12: repetition of the same sequence applied for days 1 to 5, and smart control enabled,
— days 13 and 14: no water draw-offs, and smart control enabled,
— the difference between the useful energy content measured during days 1 to 7 and the useful energy content
measured during days 8 to 14 shall not exceed 2 % of Q ref of the declared load profile.
4. Conditions for testing solar water heaters
The solar collector, solar hot water storage tank, pump in the collector loop (if applicable) and heat generator shall be
tested separately. Where the solar collector and solar hot water storage tank cannot be tested separately, they shall be
tested in combination. The heat generator shall be tested under the conditions set out in point 2 of this Annex.
The results shall be used for the calculations set out in point 3(b) of Annex VIII under the conditions set out in Tables
4 and 5. For the purpose of establishing Q tota the efficiency of the heat generator using the Joule effect in electric
resistance heating elements is assumed to be 100/CC, expressed in %.
5. Conditions for testing heat pump water heaters
— Heat pump water heaters shall be tested under the conditions set out in Table 6,
— Heat pump water heaters which use ventilation exhaust air as the heat source shall be tested under the conditions
set out in Table 7.
6. Conditions for testing solar devices
The solar collector, solar hot water storage tank and pump in the collector loop (if applicable) shall be tested
separately. Where the solar collector and solar hot water storage tank cannot be tested separately, they shall be
tested in combination.
The results shall be used for the calculations of Q nonsol for the load profiles M, L, XL and XXL under the average
climate conditions set out in Tables 4 and 5 and Q aux .

6.9.2013 Off
Table 4
Average daytime temperature [°C]
January February March April May June July August September October November December
Average climate conditions +
2,8 +
2,6 +
7,4 +
12,2 +
16,3 +
19,8 +
21,0 +
22,0 +
17,0 +
11,9 +
5,6 +
3,2
EN
Colder climate conditions –
3,8 –
4,1 –
0,6 +
5,2 +
11,0 +
16,5 +
19,3 +
18,4 +
12,8 +
6,7 +
1,2 –
3,5

Warmer climate conditions +
9,5 +
10,1 +
11,6 +
15,3 +
21,4 +
26,5 +
28,8 +
27,9 +
23,6 +
19,0 +
14,5 +
10,4
Table 5
Average global solar irradiance [W/m2 ]
January February March April May June July August September October November December
icial
Average climate conditions 70 104 149 192 221 222 232 217 176 129 80 56
Jour
Colder climate conditions 22 75 124 192 234 237 238 181 120 64 23 13
nal
Warmer climate conditions 128 137 182 227 248 268 268 263 243 175 126 109
of
the
European
Table 6
Standard rating conditions for heat pump water heaters, temperatures in dry bulb air temperature (wet bulb air temperature in brackets)
Union
Heat source Outdoor
air Indoor
air Exhaust
air Brine Water
Climate conditions Average
climate
conditions Colder
climate
conditions Warmer
climate
conditions Not
applicable All
climate
conditions
Temperature +
7
°C
(+
6
°C) +
2
°C
(+
1
°C)
+ 14 °C (+ 13 °C) +
20
°C
+ 20 °C
0 °C (inlet)/
+ 10 °C (inlet)/
(maximum + 15 °C)
(+ 12 °C)
– 3 °C (outlet)
+ 7 °C (outlet)
L
239/129


L 239/130
EN
Official Journal of the European Union
6.9.2013
Table 7
Maximum ventilation exhaust air available [m 3 /h], at a temperature of 20 °C and with humidity of 5,5 g/m 3
Declared load profile XXS XS
S
M
L XL XXL
Maximum ventilation exhaust air available 109 128 128 159 190 870 1
021
7. Technical parameters of water heaters
The following parameters shall be established for water heaters:
(a) the daily electricity consumption Q elec in kWh, rounded to three decimal places;
(b) the declared load profile, expressed by the appropriate letter in accordance with Table 3 of this Annex;
(c) the sound power level in dB, indoors, rounded to the nearest integer (for heat pump water heaters, if applicable);
in addition, for water heaters using fossil and/or biomass fuels:
(d) the daily fuel consumption Q fuel in kWh in terms of GCV, rounded to three decimal places;
in addition, for water heaters for which the value of smart is declared as being ‘1’:
(e) the weekly fuel consumption with smart controls Q fuel,week,smart in kWh in terms of GCV, rounded to three decimal
places;
(f) the weekly electricity consumption with smart controls Q elec,week,smart in kWh, rounded to three decimal places;
(g) the weekly fuel consumption without smart controls Q fuel,week in kWh in terms of GCV, rounded to three decimal
places;
(h) the weekly electricity consumption without smart controls Q elec,week in kWh, rounded to three decimal places;
in addition, for solar water heaters:
(i) the
collector
aperture
area A sol in m 2 , rounded to two decimal places;
(j) the zero-loss efficiency η 0 , rounded to three decimal places;
(k) the first-order coefficient a 1 in W/(m 2 K), rounded to two decimal places;
(l) the
second-order
coefficient a 2 in W/(m 2 K 2 ), rounded to three decimal places;
(m) the incidence angle modifier IAM, rounded to two decimal places;
(n) the pump power consumption solpump in W, rounded to two decimal places;
(o) the standby power consumption solstandby in W, rounded to two decimal places;
in addition, for heat pump water heaters:
(p) the sound power level L WA in dB, outdoors, rounded to the nearest integer.
8. Technical parameters of hot water storage tanks
The following parameters shall be established for hot water storage tanks:
(a) the storage volume V in litres, rounded to one decimal place;
(b) the standing loss S in W, rounded to one decimal place.

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/131
9. Technical parameters of solar devices
The following parameters shall be established for solar devices:
(a) the collector aperture area A sol in m 2 , rounded to two decimal places;
(b) the zero-loss efficiency η 0 , rounded to three decimal places;
(c) the first-order coefficient a 1 in W/(m 2 K), rounded to two decimal places;
(d) the second-order coefficient a 2 in W/(m 2 K 2 ), rounded to three decimal places;
(e) the incidence angle modifier IAM, rounded to two decimal place;
(f) the pump power consumption solpump in W, rounded to two decimal places;
(g) the standby power consumption, solstandby in W, rounded to two decimal places.

L 239/132
EN
Official Journal of the European Union
6.9.2013
ANNEX VIII
Method for calculating the water heating energy efficiency of water heaters
1. For the purposes of compliance and verification of compliance with the requirements of this Regulation, calculations
shall be made using harmonised standards the reference numbers of which have been published for this purpose in the
Official Journal of the European Union, or using other appropriate calculation methods that take into account the
generally recognised state-of-the-art methods. They shall meet the technical parameters and calculations set out in
points 2 to 6.
Technical parameters used for the calculations shall be measured in accordance with Annex VII.
2. Technical parameters of water heaters
The following parameters shall be calculated for water heaters under average climate conditions:
(a) the water heating energy efficiency η wh in %, rounded to one decimal place;
(b) the annual electricity consumption AEC in kWh in terms of final energy, rounded to the nearest integer;
in addition, for water heaters using fuels under average climate conditions:
(c) the annual fuel consumption AFC in kWh in terms of GCV, rounded to the nearest integer;
in addition, for solar water heaters under average climate conditions:
(d) the heat generator water heating energy efficiency η wh,nonsol in %, rounded to one decimal place;
(e) the annual auxiliary electricity consumption Q aux in kWh in terms of final energy, rounded to one decimal place;
in addition, for solar water heaters and heat pump water heaters under colder and warmer climate conditions:
(f) the parameters set out in points (a) to (c);
in addition for solar water heaters under average, colder and warmer climate conditions:
(g) the annual non-solar heat contribution Q nonsol in kWh in terms of primary energy for electricity and/or in kWh in
terms of GCV for fuels, rounded to one decimal place.
3. Calculation of the water heating energy efficiency η wh
(a) Conventional water heaters and heat pump water heaters:
The water heating energy efficiency is calculated as follows:
Q
η
ref

wh

Q fuel CC Q elec 1 SCF smart Q cor
For water-/brine-to-water heat pump water heaters, the electricity consumption of one or more ground water
pumps shall be taken into account.
(b) Solar water heaters:
The water heating energy efficiency is calculated as follows:
0,6 366 Q
η
ref

wh
Q tota

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/133
Where:
Q
Q

nonsol

tota 1,1 η wh;nonsol 0,1 Q aux CC
4. Calculation of the annual electricity consumption AEC and the annual fuel consumption AFC
(a) Conventional water heaters and heat pump water heaters:
The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
Q
AEC

cor
0,6 366 Q elec 1 SCF smart
CC
The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
AFC 0,6 366 Q fuel 1 SCF smart Q cor
(b) Solar water heaters:
The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
CC Q
Q
AEC


tota

elec

Q fuel CC Q elec CC
The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
Q
AFC
fuel

Q
Q

tota

fuel CC Q elec
5. Determination of the smart control factor SCF and of smart control compliance smart
(a) The smart control factor is calculated as follows:
Q
SCF
fuel
1 ;week;smart CC Q elec;week;smart
Q fuel;week CC Q elec;week
(b) If SCF ≥ 0,07, the value of smart shall be 1. In all other cases, the value of smart shall be 0.
6. Determination of the ambient correction term Q cor
The ambient correction term is calculated as follows:
(a) for conventional water heaters using electricity:
Q cor k CC Q elec 1 SCF smart Q ref
(b) for conventional water heaters using fuels:
Q cor k Q fuel 1 SCF smart Q ref
(c) for heat pump water heaters:
Q cor k 24h P stby

L 239/134
EN
Official Journal of the European Union
6.9.2013
Where:
the k-values are given in Table 8 for each load profile.
Table 8
k-values
3XS XXS XS
S
M
L XL XXL
k 0,23 0,23 0,23 0,23 0,23 0,23 0,23 0,0

EN
6.9.2013 Official
Journal
of
the
European
Union
L
239/135
ANNEX IX
Verification procedure for market surveillance purposes
For the purposes of assessing the conformity with the requirements laid down in Articles 3 and 4, Member State
authorities shall test a single water heater, hot water storage tank, solar device or package of water heater and solar
device and provide the information on the test results to the authorities of the other Member States. If the measured
parameters do not meet the values declared by the supplier within the ranges set out in Table 9, the measurement shall be
carried out on three additional water heaters, hot water storage tanks, solar devices or packages of water heater and solar
device and the information on the test results shall be provided to the authorities of the other Member States and to the
Commission within one month of testing. The arithmetic mean of the measured values of these three water heaters, hot
water storage tanks, solar devices or packages of water heater and solar device shall meet the values declared by the
supplier within the range set out in Table 9.
Otherwise, the model and all other equivalent water heater models, hot water storage tanks models, solar device models
or package of water heater and solar device models shall be considered not to comply.
Member State authorities shall use the procedures set out in Annexes VII and VIII.
Table 9
Verification tolerances
Measured parameter Verification
tolerance
Daily electricity consumption Q elec
The measured value shall not be more than 5 % higher
than the rated value (*).
Sound power level L WA , indoors and/or outdoors The
measured
value
shall
not
be
more
than
2
dB
higher
than the rated value.
Daily fuel consumption Q fuel
The measured value shall not be more than 5 % higher
than the rated value.
Weekly fuel consumption with smart controls Q fuel,week,smart The measured value shall not be more than 5 % higher
than the rated value.
Weekly fuel consumption without smart controls Q fuel,week The measured value shall not be more than 5 % higher
than the rated value.
Weekly electricity consumption with smart controls The measured value shall not be more than 5 % higher
Q elec,week,smart
than the rated value.
Weekly electricity consumption without smart controls The measured value shall not be more than 5 % higher
Q elec,week
than the rated value.
Collector aperture area A sol
The measured value shall not be more than 2 % lower than
the rated value.
Pump power consumption solpump The
measured
value
shall
not
be
more
than
3
%
higher
than the rated value.
Standby power consumption solstandby The
measured
value
shall
not
be
more
than
5
%
higher
than the rated value.
Storage volume V The
measured
value
shall
not
be
more
than
2
%
lower
than
the rated value.
Standing loss S The
measured
value
shall
not
be
more
than
5
%
higher
than the rated value.
(*) ‘Rated value’ means the value declared by the supplier.

Document Outline


附件:

P020171219417654782329.pdf

托管标准,您可以接收以下服务:

1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;

2 随时在标准托管页面中查看到该条标准的最新状态;

3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;

4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;

5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;

6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;

进入企业标准托管

您可以通过编辑查新模板,批量查询指定标准集的最新情况。我们会通过查询,向您展示您所查询标准的:

1. 准确的标准号及标准名称(我们通过人工智能技术对您提交的标准号进行自动纠正)

2. 标准的最新状态(现行、废止或未发布)

3. 若标准已废止并被新标准替代,会反馈被替代的标准

4. 若您已托管此标准,便可以实时跟踪这个标准的最新状态

标准查新 模板下载

您可以在这里检索全球超过140万条标准,支持上百个国内国际标准组织的标准查询。您也可以在这里检索国内各类国家、部委和地方的法律法规。

更多标准子库在持续建设中。

标准检索

标准资讯点击排行榜 全部

资讯标题点击

[[ n.title ]] [[ n.read ]]

大连标准化公共服务平台

版权:大连标准化研究院有限公司

地址:大连市中山区高原街56号

电话:0411-82740851

大连标准