第7个委员会指令96/45/EC,关于检查化妆品成份的强制性分析方法

技术法规类型:欧盟Eurlex法规 来源:tbtmap

EURLEX ID:31996L0045

OJ编号:OJ L 213, 22.8.1996, p. 8-15

中文标题:第7个委员会指令96/45/EC,关于检查化妆品成份的强制性分析方法

原文标题:Seventh Commission Directive 96/45/EC of 2 July 1996 relating to methods of analysis necessary for checking the composition of cosmetic products (Text with EEA relevance)

分类:13.30.16_化妆品

文件类型:二级立法 Directive|指令

生效日期:1996-09-11

废止日期:2058-12-31

法规全文:查看欧盟官方文件

EUR-Lex - 31996L0045 - EN
| EUROPA > EUR-Lex > ID celex

31996L0045


Title and reference

Seventh Commission Directive 96/45/EC of 2 July 1996 relating to methods of analysis necessary for checking the composition of cosmetic products (Text with EEA relevance)

OJ L 213, 22.8.1996, p. 8‘�5 (ES, DA, DE, EL, EN, FR, IT, NL, PT, FI, SV)
Special edition in Czech Chapter 13 Volume 017 P. 142 - 149
Special edition in Estonian Chapter 13 Volume 017 P. 142 - 149
Special edition in Hungarian Chapter 13 Volume 017 P. 142 - 149
Special edition in Lithuanian Chapter 13 Volume 017 P. 142 - 149
Special edition in Latvian Chapter 13 Volume 017 P. 142 - 149
Special edition in Maltese Chapter 13 Volume 017 P. 142 - 149
Special edition in Polish Chapter 13 Volume 017 P. 142 - 149
Special edition in Slovakian Chapter 13 Volume 017 P. 142 - 149
Special edition in Slovenian Chapter 13 Volume 017 P. 142 - 149

DA DE EL EN ES FI FR IT NL PT SV

Text

BG ES CS DA DE ET EL EN FR GA IT LV LT HU MT NL PL PT RO SK SL FI SV
html html html html html html html html html html html html html html html html html html html html html html
pdf pdf pdf pdf pdf pdf pdf pdf pdf pdf pdf
tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff tiff

Authentic language

  • The official languages, Icelandic, Norwegian

Dates

    of document: 02/07/1996
    of effect: 11/09/1996; Entry into force Date pub. + 20 See Art 3
    end of validity: 99/99/9999
    of transposition: 30/09/1997; At the latest See Art 3

Classifications

Miscellaneous information

  • Author:
    European Commission
  • Form:
    Directive
  • Addressee:
    The Member States
  • Additional information:
    Extended to the EEA by 21998D0205(07) EEA relevance

Relationship between documents

Text

Bilingual display: BG CS DA DE EL EN ES ET FI FR HU IT LT LV MT NL PL PT RO SK SL SV

SEVENTH COMMISSION DIRECTIVE 96/45/EC of 2 July 1996 relating to methods of analysis necessary for checking the composition of cosmetic products (Text with EEA relevance)

THE COMMISSION OF THE EUROPEAN COMMUNITIES,

Having regard to the Treaty establishing the European Community,

Having regard to Council Directive 76/768/EEC of 27 July 1976 on the approximation of the laws of the Member States relating to cosmetic products (1), as last amended by Commission Directive 95/34/EC (2), and in particular Article 8 (1) thereof,

Whereas Directive 76/768/EEC provides for the official testing of cosmetic products with the aim of ensuring that the conditions laid down by Community provisions concerning the composition of cosmetic products are satisfied;

Whereas all the necessary methods of analysis should be laid down as quickly as possible; whereas certain methods have already been adopted in Commission Directives 80/1335/EEC (3), as amended by Directive 87/143/EEC (4), 82/434/EEC (5), as amended by Directive 90/207/EEC (6), and by Commission Directives 83/514/EEC (7), 85/490/EEC (8), 93/73/EEC (9) and 95/32/EC (10);

Whereas the identification and determination of 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl, ethyl, propyl, butyl and benzyl 4-hydroxybenzoate in cosmetic products constitute a seventh step;

Whereas the measures provided for in this Directive are in accordance with the opinion of the Committee on the adaptation of Directive 76/768/EEC to technical progress,

HAS ADOPTED THIS DECISION:

Article 1

Member States shall take all the necessary steps to ensure that during official testing of cosmetic products, the identification and determination of 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl, ethyl, propyl, butyl and benzyl 4-hydroxybenzoate shall be carried out in accordance with the method described in the Annex.

Article 2

1. Member States shall bring into force the laws, regulations and administrative provisions needed to comply with this Directive no later than 30 September 1997. They shall forthwith inform the Commission thereof.

2. When Member States adopt these provisions, these shall contain a reference to this Directive or shall be accompanied by such reference at the time of their official publication. The procedure for such reference shall be adopted by the Member States.

3. Member States shall communicate to the Commission the provisions of national law which they adopt in the field covered by this Directive.

Article 3

This Directive shall enter into force on the 20th day following its publication in the Official Journal of the European Communities.

Article 4

This Directive is addressed to the Member States.

Done at Brussels, 2 July 1996.

For the Commission

Emma BONINO

Member of the Commission

(1) OJ No L 262, 27. 9. 1976, p. 169.

(2) OJ No L 167, 18. 7. 1995, p. 19.

(3) OJ No L 383, 31. 12. 1980, p. 27.

(4) OJ No L 57, 27. 2. 1987, p. 56.

(5) OJ No L 185, 30. 6. 1982, p. 1.

(6) OJ No L 108, 28. 4. 1990, p. 92.

(7) OJ No L 291, 24. 10. 1983, p. 9.

(8) OJ No L 295, 7. 11. 1985, p. 30.

(9) OJ No L 231, 14. 9. 1993, p. 34.

(10) OJ No L 178, 28. 7. 1995, p. 20.

ANNEX

IDENTIFICATION AND DETERMINATION OF 2-PHENOXYETHANOL, 1-PHENOXYPROPAN-2-OL, METHYL, ETHYL, PROPYL, BUTYL AND BENZYL 4-HYDROXYBENZOATE IN COSMETIC PRODUCTS

A. IDENTIFICATION

1. Scope and field of application

This method specifies a TLC procedure that, in combination with the determination method described in Section B, allows the identification of 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl 4-hydroxybenzoate, ethyl 4-hydroxybenzoate, propyl 4-hydroxybenzoate, butyl 4-hydroxybenzoate and benzyl 4-hydroxybenzoate in cosmetic products.

2. Principle

The preservatives are extracted from the acidified cosmetic sample with acetone. After filtration, the acetone solution is mixed with water, and in an alkaline medium the fatty acids are precipitated as their calcium salts. The alkaline acetone/water mixture is extracted with diethylether to remove lipophilic substances. After acidification the preservatives are extracted with diethylether. An aliquot of the diethylether extract is spotted on a silica-gel coated thin-layer plate. After development of the plate, the chromatogram obtained is observed under UV light and visualized using Millon's reagent.

3. Reagents

3.1. General

All reagents used shall be of analytical purity. Water shall be distilled water, or water of at least equal purity.

3.2. Acetone

3.3. Diethylether

3.4. n-Pentane

3.5. Methanol

3.6. Acetic acid, glacial

3.7. Hydrochloric acid solution, c(HCl)=4mol/l

3.8. Potassium hydroxide solution, c(KOH)=4 mol/l

3.9. Calcium chloride dihydrate (CaCl2 72H2O)

3.10. Detection reagent: Millon's reagent

Millon's reagent (Mercury (II) nitrate) is a ready-made solution which is commercially available (Fluka 69820).

3.11. 2-Phenoxyethanol

3.12. 1-Phenoxypropan-2-ol

3.13. Methyl 4-hydroxybenzoate (methylparaben)

3.14. Ethyl 4-hydroxybenzoate (ethylparaben)

3.15. n-Propyl 4-hydroxybenzoate (propylparaben)

3.16. n-Butyl 4-hydroxybenzoate (butylparaben)

3.17. Benzyl 4-hydroxybenzoate (benzylparaben)

3.18. Reference solutions

Prepare 0,1 % (m/V) solutions of each of the reference substances 3.11, 3.12, 3.13, 3.14, 3.15, 3.16 and 3.17 in methanol.

3.19. Development solvent

Mix 88 volumes of n-pentane (3.4) with 12 volumes of glacial acetic acid (3.6).

4. Apparatus

Normal laboratory equipment, and:

4.1. Waterbath, capable of maintaining a temperature of 60 掳C

4.2. Developing tank (not lined with filter paper)

4.3. Ultraviolet light source, 254 nm

4.4. Thin-layer plates, 20 cm × 20 cm, precoated with 0,25 mm silica gel 60F254, with concentrating zone (Merck No 11798, Darmstadt, or equivalent)

4.5. Oven, capable of maintaining up to 105 掳C

4.6. Hot-air hair dryer

4.7. Woollen paint roller, length approximately 10 cm, outside diameter approximately 3,5 cm. The thickness of the wool-layer shall be 2 to 3 mm. Trim the wool if necessary.

See note under 5.2

4.8. 50-ml glass tubes with screw cap

4.9. Electric heating plate, with thermostatic temperature controller. Temperature setting: about 80 掳C. The hot plate shall be covered with an aluminium plate of 20 cm × 20 cm and a thickness of about 6 mm, to obtain a uniform heat distribution.

5. Procedure

5.1. Sample preparation

Weigh approximately 1 g of sample in a 50-ml glass tube with screw cap (4.8). Add four drops of hydrochloric acid solution (3.7) and 40 ml of acetone.

For strongly basic cosmetic products, such as toilet-soap, 20 drops of hydrochloric acid solution shall be added. Close the tube, gently heat the mixture to approximately 60 掳C to facilitate the extraction of the preservatives into the acetone phase and shake vigourously for one minute.

Measure the pH of the solution with pH indicator paper and adjust the pH of the solution ≤ 3 with hydrochloric acid solution. Shake vigorously again for one minute.

Cool the solution to room temperature and filter through a filter paper into a conical flask. Transfer 20 ml of the filtrate into a 200-ml conical flask, add 60 ml water and mix. Adjust the pH of the mixture to approximately 10 with potassium hydroxide (3.8), using pH indicator paper.

Add 1 g calcium chloride dihydrate (3.9) and shake vigorously. Filter the solution through a filter paper into a 250-ml separating funnel containing 75 ml diethylether and shake vigorously for one minute. Allow the phases to separate and collect the aqueous layer in a 200-ml conical flask. Adjust the pH of the solution to approximately 2 with hydrochloric acid solution, using pH indicator paper. Subsequently, add 10 ml diethylether and shake vigorously for one minute. Allow the phases to separate and transfer approximately 2 ml of the diethylether layer into a 5-ml sample vial.

5.2. Thin-layer chromatography (TLC)

Place a TLC plate (4.4) on the heated aluminium plate (4.9). Apply 10 矛l of each of the reference solutions (3.18) and 100 矛l of the sample solution(s) (5.1) on a start line in the concentration zone of the TLC plate.

If desired, a stream of air can be used to facilitate evaporation of the solvent. Remove the TLC plate from the heating plate and allow to cool to room temperature. Transfer 100 ml of the development solvent (3.19) into a developing tank (4.2).

Place the TLC plate immediately in the unsaturated chamber and develop at room temperature until the solvent front has run about 15 cm from the base line. Remove the plate from the development tank and dry in a stream of hot air by means of a hot-air hair dryer.

Examine the plate under UV light (4.3) and mark the position of the spots. Heat the plate for 30 minutes in an oven (4.5) at 100 掳C to remove excess acetic acid. Visualize the preservatives in the chromatogram with Millon's reagent (3.10), by dipping the paint roller (4.7) into the reagent and rolling over the TLC-plate until evenly wetted.

Note: Alternatively, the spots may be visualized by the careful application of a drop of Millon's reagent on each of the spots marked under UV light.

Esters of 4-hydroxybenzoic acid appear as red spots, 2-phenoxyethanol and 1-phenoxypropan-2-ol as yellow spots. Note, however, that 4-hydroxybenzoic acid itself, which may be present in the samples as a preservative or decomposition product of the parabens, will also appear as a red spot. See 7.3 and 7.4.

6. Identification

Calculate the Rf-value for each spot. Compare the spots obtained from the sample solution with those of the reference solutions with respect to their Rf-values, their behaviour under UV radiation and the colour after visualization. Draw preliminary conclusions about the identity of the preservatives.

If parabens appear to be present, the HPLC procedure described in Section B should be performed. Combine the results from TLC and high-performance liquid chromatography (HPLC) to confirm the presence of the 2-phenoxyethanol, 1-phenoxypropan-2-ol and the parabens.

7. Remarks

7.1. Because of the toxicity of Millon's reagent this reagent is best applied by one of the procedures described. Spraying is not recommended.

7.2. Other compounds containing hydroxyl groups may also give colours with Millon's reagent. A table of colours and Rf-values obtained for a number of preservatives using this TLC procedure may be found in: N. de Kruijf, M. A. H. Rijk, L. A. Pranato-Soetardhi and A. Schouten (1987): Determination of preservatives in cosmetic products I: Thin-layer chromatographic procedure for the identification of preservatives in cosmetic products (J. Chomatography 410, 395-411).

7.3. The Rf-values listed in the following table serve as an indication of the values that may be obtained:

>TABLE>

7.4. No separation is obtained for 4-hydroxybenzoic acid and methylparaben, or for benzylparaben and ethylparaben. Identification of these compounds should be confirmed by performing the HPLC method described under Section B and comparing the retention times obtained from the sample with those of standards.

B. DETERMINATION

1. Scope and field of application

This method specifies a procedure for the determination of 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl 4-hydroxybenzoate, ethyl 4-hydroxybenzoate, propyl 4-hydroxybenzoate, butyl 4-hydroxybnenzoate and benzyl 4-hydroxybenzoate in cosmetic products.

2. Definition

The amounts of the preservatives determined by this method are expressed as percentage by mass.

3. Principle

The sample is acidified by adding sulfuric acid and then suspended in a mixture of ethanol and water. After gently heating the mixture to melt the lipid phase to promote quantitative extraction, the mixture is filtered.

The preservatives in the filtrate are determined by reversed phase HPLC using isopropyl 4-hydroxybenzoate as the internal standard.

4. Reagents

4.1. General

All reagents must be of analytical purity and suitable for HPLC where appropriate. Water shall be distilled water, or water of at least equal purity.

4.2. Ethanol, absolute

4.3. 2-Phenoxyethanol

4.4. 1-Phenoxypropan-2-ol

4.5. Methyl 4-hydroxybenzoate (methylparaben)

4.6. Ethyl 4-hydroxybenzoate (ethylparaben)

4.7. n-Propyl 4-hydroxybenzoate (propylparaben)

4.8. Isopropyl 4-hydroxybenzoate (isopropylparaben)

4.9. n-Butyl 4-hydroxybenzoate (butylparaben)

4.10. Benzyl 4-hydroxybenzoate (benzylparaben)

4.11. Tetrahydrofuran

4.12. Methanol

4.13. Acetonitrile

4.14. Sulfuric acid solution c(H2SO4)=2mol/l

4.15. Ethanol/water mixture

Mix nine volumes of ethanol (4.2) and one volume of water.

4.16. Internal standard solution

Accurately weigh approximately 0,25 g isopropylparaben (4.8), transfer to a 500-ml volumetric flask, dissolve and make up to volume with ethanol/water mixture (4.15).

4.17. Mobile phase: tetrahydrofuran/water/methanol/acetonitrile mixture

Mix 5 volumes of tetrahydrofuran, 60 volumes of water, 10 volumes of methanol and 25 volumes of acetonitrile.

4.18. Preservative stock solution

Accurately weigh approximately 0,2 g 2-phenoxyethanol, 0,2 g 1-phenoxypropan-2-ol, 0,05 g methylparaben, 0,05 g ethylparaben, 0,05 g propylparaben, 0,05 g butylparaben and 0,025 g benzylparaben in a 100-ml volumetric flask, dissolve and make up to volume with ethanol/water mixture.

Kept in a refrigerator the solution is stable for one week.

4.19. Standard preservative solutions

From the stock solution (4.18) transfer respectively 20,00 ml, 10,00 ml, 5,00 ml, 2,00 ml and 1,00 ml into 50-ml volumetric flasks. To each flask, add 10,00 ml internal standard solution (4.16) and 1,0 ml sulfuric acid solution (4.14) and make up to volume with ethanol/water mixture. These solutions should be freshly prepared.

5. Apparatus

Normal laboratory equipment, and:

5.1. Waterbath, capable of maintaining a temperature of 60 掳C 卤 1 掳C.

5.2. High performance liquid chromatograph with a UV-detector, wavelength 280 nm

5.3. Analytical column:

Stainless steel, 25 cm × 4,6 mm i.d. (or 12,5 cm × 4,6 mm i.d.) packed with Nucleosil 5C18, or equivalent (see 10.1)

5.4. 100-ml glass tubes with screw cap

5.5. Boiling chips, carborundum, size 2 to 4 mm, or equivalent

6. Procedure

6.1. Sample preparation

6.1.1. Sample preparation without addition of the internal standard

Weigh approximately 1,0 g of sample in a 100-ml glass tube with screw cap. Pipette 1,0 ml sulfuric acid solution (4.14) and 50,0 ml ethanol/water mixture (4.15) into the tubes. Add approximately 1 g of boiling chips (5.5), close the tube and shake vigorously until a homogeneous suspension is obtained. Shake for at least one minute. Place the tube for five minutes in a waterbath (5.1) kept at 60 掳C 卤 1 掳C to facilitate the extraction of the preservatives into the ethanol phase.

Immediately cool the tube in a stream of cold water and store the extract in the refrigerator for one hour. Filter the extract using a filter paper. Transfer approximately 2 ml of the filtrate into a 5-ml sample vial. Store the extracts in the refrigerator and perform the HPLC determination within 24 hours.

6.1.2. Sample preparation including addition of internal standard

Weigh to three decimal places 1,0 g 卤 0,1 g of sample in a 100-ml glass tube with screw cap.

Pipette 1,0 ml sulfuric acid solution and 40,0 ml ethanol/water mixture into the tube. Add approximately 1 g of boiling chips (5.5) and exactly 10,00 ml internal standard solution. Close the tube and shake vigorously until a homogeneous suspension is obtained. Shake for at least one minute. Place the tube for five 5 minutes in a waterbath kept at 60 掳C 卤 1 掳C to facilitate extraction of the preservatives into the ethanol phase.

Immediately cool the tube in a stream of cold tap water and store the extract in the refrigerator for one hour. Filter the extract using a filter paper.

Transfer approximately 2 ml of the filtrate into a 5-ml sample vial (test solution). Store the extract in the refrigerator and perform the HPLC determinations within 24 hours.

6.2. High-performance liquid chromatography (HPLC)

6.2.1. Chromatographic conditions

- Mobile phase: tetrahydrofuran/water/methanol/acetonitrile mixture (4.17)

- Flow rate: 1,5 ml/minute

- Detection wavelength: 280 nm

6.2.2. Calibration

Inject 10矛l of each of the standard preservative solutions (4.19). From the chromatograms obtained determine the ratios of the peak heights of the standard preservative solutions to the peak height of the internal standard. Plot a curve for each preservative relating these ratios to the concentrations of the standard solutions.

6.2.3. Determination

Inject 10 矛l of the sample solution without internal standard (6.1.1) into the chromatograph and record the chromatogram.

Inject 10 矛l of one of the standard preservative solutions (4.19) and record the chromatogram. Compare the chromatograms obtained.

If, in the chromatogram of the sample extract (6.1.1), no peak is present having approximately the same retention time as isopropylparaben (recommended internal standard), continue by injecting 10 矛l sample solution with internal standard (6.1.2). Record the chromatogram and measure the peak heights.

If an interfering peak is observed in the chromatogram of the sample solution having approximately the same retention time as isopropylparaben, another internal standard should be selected.

If one of the preservatives under examination is absent in the chromatogram of the sample, this preservative can be used as an alternative internal standard.

Calculate the ratios of the peak heights of the investigated preservatives to the peak height of the internal standard.

Ascertain that for the standard solutions used in the calibration procedure a linear response is obtained.

Ascertain whether the chromatograms obtained for a standard solution and the sample solution meet the following requirements:

- the peak separation of the worst separated pair shall be at least 0,90. (For definition of peak separation, see Figure 1).

>REFERENCE TO A FILM>

peak separation (p)

p=f/g

Figure 1: Peak separation

If the required separation is not achieved, either a more efficient column should be used, or the mobile phase composition should be adjusted until the requirement is met.

- the asymmetry factor As of all peaks obtained shall range between 0,9 to 1,5. (For definition of the peak asymmetry factor, see Figure 2.) To record the chromatogram for the determination of the asymmetry factor a chart speed of at least 2 cm/minute is recommended.

>REFERENCE TO A FILM>

Asymmetry factor (As)

As=b/a

Figure 2: Peak asymmetry factor

- A steady baseline shall be obtained.

7. Calculation

Use the calibration curve (6.2.2) and the ratios of the peak heights of the investigated preservatives to the peak height of the internal standard to calculate the concentration of the preservatives in the sample solution. Calculate the 2-phenoxyethanol, 1-phenoxypropan-2-ol, methyl 4-hydroxybenzoate, ethyl 4-hydroxybenzoate, propyl 4-hydroxybenzoate, butyl 4-hydroxybenzoate and benzyl 4-hydroxybenzoate contents, wi, as percentage by weight (% m/m), using the formula:

% wi (m/m) = >NUM>bi >DEN>200 × a

in which:

bi = the concentration (矛g/ml) of preservative i in the test solution as read from the calibration curve; and

a = the mass (g) of the test position.

8. Repeatability (1)

See remarks, 10.5.

9. Reproducibility (2)

See remarks, 10.5.

10. Remarks

10.1. Stationary phase

The retention behaviour of the solutes in HPLC determinations is strongly dependent on the type, the brand and the history of the stationary phase. Whether a column can be used for the separation of the preservatives under examination, can be concluded from the results obtained for standard solutions (see remarks 6.2.3). In addition to the proposed column packing material, Hypersil ODS and Zorbax ODS were also found to be suitable.

Alternatively, the recommended mobile phase composition can be optimized in order to obtain the required separation.

10.2. Detection wavelength

A ruggedness test on the described method has shown that a slight change in the detection wavelength can have a significant effect on the results of the determination.

Therefore, this parameter must be controlled carefully during the analysis.

10.3. Interferences

Under the conditions described in this method many other compounds, such as preservatives and cosmetic additives, are eluted as well. Retention times of a large number of preservatives mentioned in Annex VI to the Council Directive regarding cosmetic products are listed in: N. de Kruijf, M. A. H. Rijk, L. A. Pranato-Soetardhi and A. Schouten, (1989). Determination of preservatives in cosmetic products II. High-performance liquid chromatographic identification (J. Chromatography 469, 317-398).

10.4. To project the analytical column an appropriate guard column may be used.

10.5. The method has been investigated in a collaborative trial in which nine laboratories participated. Three samples were analyzed. The following table lists, for each of the three samples, the means in % m/m (m), repeatabilities (r), reproducibilities (R) found for the analytes they contained:

>TABLE>

(1) ISO 5725.

Top

托管标准,您可以接收以下服务:

1 标准定期系统查新,若有最新版本,会以站内短信或邮件的形式通知用户;

2 随时在标准托管页面中查看到该条标准的最新状态;

3 若用户有在学习和科研中的需要,可以在标准托管页面中试阅标准;

4 企业如果需要上新产品,我院及时提供标准查询、采购等方面的支持;

5 为企业在标准制修订、企业良好行为创建以及标准化试点过程中遇到的困难,可联系我院指定相关专家负责进行指导帮助、提供政策咨询;

6 为企业提供标准化政策的解读、标准化知识的推广培训、标准自我公开声明、标准文献的免费查询、企业标准化体系建设等方面的标准化服务;

进入企业标准托管

您可以通过编辑查新模板,批量查询指定标准集的最新情况。我们会通过查询,向您展示您所查询标准的:

1. 准确的标准号及标准名称(我们通过人工智能技术对您提交的标准号进行自动纠正)

2. 标准的最新状态(现行、废止或未发布)

3. 若标准已废止并被新标准替代,会反馈被替代的标准

4. 若您已托管此标准,便可以实时跟踪这个标准的最新状态

标准查新 模板下载

您可以在这里检索全球超过140万条标准,支持上百个国内国际标准组织的标准查询。您也可以在这里检索国内各类国家、部委和地方的法律法规。

更多标准子库在持续建设中。

标准检索

标准资讯点击排行榜 全部

资讯标题点击

[[ n.title ]] [[ n.read ]]

大连标准化公共服务平台

版权:大连标准化研究院有限公司

地址:大连市中山区高原街56号

电话:0411-82740851

大连标准